To adjust the compression damping
force (for slow compression damping)
To increase the compression damping
force and thereby harden the com-
pression damping, turn the adjusting
bolt on each fork leg in direction (a). To
decrease the compression damping
force and thereby soften the compres-
sion damping, turn the adjusting bolt
on each fork leg in direction (b).
TIP
Although the total number of clicks or
turns of a damping force adjusting
mechanism may not exactly match the
above specifications due to small dif-
ferences in production, the actual
number of clicks or turns always repre-
sents the entire adjusting range. To ob-
tain a precise adjustment, it would be
advisable to check the number of
clicks or turns of each damping force
adjusting mechanism and to modify
the specifications as necessary.
1. Compression damping force adjusting bolt
(for fast compression damping)
Compression
d
ampin
g
settin
g
(for
fast compression
d
ampin
g
):
Minimum (soft):
5.5 turn(s) in direction (b)*
Standard:
3 turn(s) in direction (b)*
Maximum (hard):
0 turn(s) in direction (b)*
* With the adjusting bolt fully turned
in direction (a)
(b)
(a)
1
1. Compression damping force adjusting bolt
(for slow compression damping)
Compression
d
ampin
g
settin
g
(for
slow compression
d
ampin
g
):
Minimum (soft):
18 click(s) in direction (b)*
Standard:
11 click(s) in direction (b)*
Maximum (hard):
0 click(s) in direction (b)*
* With the adjusting bolt fully turned
in direction (a)
(b)
(a)
1