Controls and Connectors

8 MCP1 Installation Man

u

al

Rear Panel

t

NETWORK port

This is an RJ-45 port for connection to the Dante port or [NET

W

ORK] port of the MTX/MRX 

v

ia the PSE.

The maxim

u

m ca

b

le length that can 

b

u

sed is 100 meters.

NOTE

Use STP (Shielded T

w

isted Pair) ca

b

le to pre

v

ent electromagnetic interference.

t

t

Содержание MCP1

Страница 1: ...guês Italiano Русский 日本語 JA RU IT PT ES FR DE EN WALL MOUNT CONTROLLER MCP1 施工説明書 Installation Manual Installationshandbuch Manuel d installation Manual de instalación Manual de instalação Manuale all installazione Руководство по установке ...

Страница 2: ... in a residential envi ronment will not result in harmful interference with other electronic devices This equipment generates uses radio frequencies and if not installed and used according to the instruc tions found in the users manual may cause interference harmful to the operation of other electronic devices Compliance with FCC reg ulations does not guarantee that interference will not occur in ...

Страница 3: ...sonnel Never insert or remove a cable with wet hands Fire warning Do not place any burning items or open flames near the device since they may cause a fire If you notice any abnormality If any of the following problems occur immediately turn off the PoE injector or the PoE network switch and disconnect the cable Unusual smells or smoke are emitted Some object has been dropped into the device Crack...

Страница 4: ...nel When cleaning the device use a dry and soft cloth Do not use paint thinners solvents cleaning fluids or chemical impregnated wiping cloths Condensation can occur in the device due to rapid drastic changes in ambient tempera ture when the device is moved from one location to another or air conditioning is turned on or off for example Using the device while condensation is present can cause dama...

Страница 5: ...cluded items Mounting plate Surface mount box Side panel 2 Main unit mounting plate screws 4 with washers Mounting plate surface mount box screws 4 without washers MCP1 installation manual this document Firmware update MTX MRX Editor is used to update the firmware of the MCP1 and to check the version For details on how to perform these operations refer to MTX MRX Editor User Guide The latest firmw...

Страница 6: ...ng the MCP1 to a wall you ll need to provide several items PoE injector or PoE network switch that supports IEEE802 3af This is used between the MTX MRX system and the MCP1 in order to supply power to the MCP1 PoE injector units and PoE network switches are collectively referred to as PSE Power Sourcing Equipment Ethernet cables CAT5e or better These are used between the MTX MRX and the PSE and be...

Страница 7: ...is locked or sleeping the lock or sleep state is defeated w L1 2 3 and R1 2 3 switches Use these switches to move from the home page to another page or to operate parameters Use MTX MRX Editor to specify the pages or parameters e Display This shows parameters and other information Use MTX MRX Editor to create the data that will be shown r Return switch After setting a parameter touch this switch t...

Страница 8: ...anel t NETWORK port This is an RJ 45 port for connection to the Dante port or NETWORK port of the MTX MRX via the PSE The maximum cable length that can be used is 100 meters NOTE Use STP Shielded Twisted Pair cable to prevent electromagnetic interference t t ...

Страница 9: ...ort PoE connect a PoE injector between the network switch and the MCP1 In some cases the PSE PoE network switch or PoE injector might have ports that supply power and ports that do not supply power Connect the MCP1 to a port that supplies power For details on how to synchronize each device refer to MTX MRX Editor User Guide Connections for a small system Connections for a large system Computer MTX...

Страница 10: ... either PC or UNIT ID as the method of specifying the MCP1 s IP address In the case of PC use MTX MRX Editor to specify the IP address In the case of UNIT ID the IP address will be 192 168 0 UNIT ID After selecting PC or UNIT ID touch the return switch to move to the confirmation screen and automatically restart Unit ID Specifies the MCP1 s UNIT ID The range of this setting is 01 through FE If IP ...

Страница 11: ...rews without washers M3 0 12 CAUTION Install the MCP1 no more than 2 meters above the floor When MCP1 falls it becomes a cause by which MCP1 is damaged or you or others are injured If embedding the unit in a gang box installed behind the wall Orient the gang box behind the wall in a horizontal position into the gang box pass the cable that is connected to the PSE If installing the unit in the incl...

Страница 12: ...uded screws with washers to secure the unit in four locations from the side 5 Power on the PSE 6 Verify that the MCP1 starts If it starts the PSE and the MCP1 are correctly connected 7 Attach the side panels to the left and right sides of the MCP1 Attach them so that they click into place Next specify the UNIT ID NOTE Do not attach the side panel yet If there is a problem with connections removing...

Страница 13: ...the L1 2 3 switches at the left to set it to UNIT ID If you are using a subnet other than 192 168 0 x set this to PC and make the setting in MTX MRX Editor 5 Touch the return switch A confirmation screen appears select Yes The setting is confirmed as the UNIT ID and the MCP1 automatically restarts 6 Touch the Unit ID switch L2 Set the MCP1 s UNIT ID Set the ID so that it does not conflict with the...

Страница 14: ...to the utility page 2 Touch the Settings switch R1 After synchronizing with MTX MRX Editor it will be necessary to enter the PIN code 3 Touch the Initialize switch L3 A confirmation screen appears select Yes Initialization begins and the MCP1 automati cally restarts NOTE When re installing the MCP1 portions of the screw holes in the mount plate may be deformed and may not properly fit into the MCP...

Страница 15: ...ditor Fault Continuing 040 The IP address conflicts Make settings so that the IP address does not conflict Error Continuing 041 The IP address was not estab lished within 60 seconds after startup If the IP Setting is set to PC use MTX MRX Editor or the DHCP server to specify the IP address Warning Continuing 042 The devices making up the MTX MRX system were not found on the network Power on all de...

Страница 16: ...Perform synchronization again using MTX MRX Editor If this does not solve the problem ini tialize the MCP1 Error Continuing 071 The UNIT ID settings when synchronization was per formed do not match the cur rent UNIT ID settings Do not change any UNIT ID s after performing synchroniza tion If you ve changed any UNIT ID s perform synchroniza tion again Error Continuing Number Content Action Type Sin...

Страница 17: ...e range 0 C 40 C Storage temperature range 20 C 60 C Maximum number of units usable simultaneously Up to 16 MCP1 units can be installed per system There are limits on the total number of units within a system that includes other devices Operating lifespan 10 years Included items Mounting plate Surface mount box Side panels Two screws 2 kinds Each 4 pcs Installation Manual Separately sold option No...

Страница 18: ...18 MCP1 Installation Manual Dimensions 149 125 20 18 38 Without surface mount box Unit mm ...

Страница 19: ...Dimensions 19 MCP1 Installation Manual 28 18 46 152 128 128 80 4 Ø4 6 152 80 With surface mount box Surface mount box Unit mm ...

Страница 20: ...nt any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products please contact your local municipality your waste disposal service or the point of sale where you purchased the items For business users in the European Union If you wish to discard electrical and ele...

Страница 21: ...149 MCP1 Installation Manual ...

Страница 22: ...Tel 46 31 89 34 00 DENMARK Yamaha Music Denmark Fillial of Yamaha Music Europe GmbH Tyskland Generatorvej 8C ST TH 2860 Søborg Denmark Tel 45 44 92 49 00 NORWAY Yamaha Music Europe GmbH Germany Norwegian Branch Grini Næringspark 1 1332 Østerås Norway Tel 47 6716 7800 RUSSIA Yamaha Music Russia LLC Room 37 entrance 7 bld 7 Kievskaya street Moscow 121059 Russia Tel 7 495 626 5005 OTHER EUROPEAN COUN...

Страница 23: ......

Страница 24: ...http download yamaha com Yamaha Downloads http www yamahaproaudio com Yamaha Pro Audio global website ZW65400 Manual Development Group 2017 Yamaha Corporation Published 04 2017 POHD A0 Printed in China ...

Отзывы: