background image

15

With the optional remote control transmitter RS-KX1, you
can operate this unit at your listening position. For details,
refer to the instruction manual supplied with the remote
control transmitter.

REMOTE CONTROL OPERATION RANGE

RESET

MEMORY

REMAIN

TAPE

COUNTER

DUBBING

INTRO SCAN

SEARCH

DECK A/B

DIR A

DIR B

MONITOR

PLAY

REC/PAUSE

STOP

REC MUTE

¤

!

!

s

REMOTE
CONTROL
TRANSMITTER

30°

30°

7 m (23 feet)

Remote sensor

MAINTENANCE

Inside of the cassette compartment

Heads

Pinch roller

CLEANING OF THE TAPE PATH

Continued high quality performance of your deck is
dependent upon periodic cleaning of the heads, capstan,
pinch roller, and all surfaces over which the tape travels.
Normal use will cause an accumulation of dirt and dust on
the heads, capstans, and pinch rollers.  This can lead to
poor sound quality, drop outs (intervals with no sound),
unsteady tape speed, loss of high frequency response,
etc.
Thus, clean the heads and all surfaces over which the
tape travels with a commercially available cleaning
cassette and fluid type cleaner.

DEMAGNETIZATION

After 20-30 hours of use, enough residual magnetism will
build up on the heads to cause poor high frequency
reproduction.  At this time you should use a commercially
available head demagnetizer.

÷

When cleaning the tape path or demagnetizing the
heads, be sure to follow carefully the instructions of the
concerning materials such as cleaning fluid or head
demagnetizer.

Capstan

OPENING AND CLOSING THE SUB PANEL

KX-580 and KX-480

  only)

OPTIONAL REMOTE CONTROL TRANSMITTER

To open the sub panel

To close the sub panel

Содержание KX 380

Страница 1: ...the serial number of your unit in the space below Model Serial No The serial number is located on the rear of the unit Retain this Owner s Manual in a safe place for future reference Í Natural Sound Stereo Cassette Deck s KX 580 KX 480 KX 380 ...

Страница 2: ... its proper ventilation For example the appliance should not be situated on a bed sofa rug or similar surfaces that may block the ventilation openings or placed in a built in installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings 9 Heat The appliance should be situated away from heat sources such as radiators stoves or other appliances that prod...

Страница 3: ...ion of America or its subsidiaries We Want You Listening For A Lifetime YAMAHA and the Electronic Industries Association s Consumer Electronics Group want you to get the most out of your equipment by playing it at a safe level One that lets the sound come through loud and clear without annoying blaring or distortion and most importantly without affecting your sensitive hearing Since hearing damage...

Страница 4: ...ear panel of your amplifier receiver if provided FEATURES 4 CONNECTIONS 4 PLAYBACK 5 SELECTION SEARCH 7 INTRO SCAN 7 MEMORY STOP operation 8 REPEAT PLAYBACK KX 580 and KX 480 only 8 RECORDING 9 REC MUTE operation 12 0 STOP operation 12 REC RETURN operation 12 TIMER RECORDING PLAYBACK KX 580 and KX 480 only 13 Timer recording 13 Timer playback 13 CASSETTE TAPES 14 OPENING AND CLOSING THE SUB PANEL ...

Страница 5: ...t push in the compartment door until it locks shut 1 2 REC PAUSE 3 STOP MPX FILTER indicator When a tape is loaded the corresponding tape type indicator lights POWER ON ŸB ŸC indicators PHONES LEVEL PHONES PLAY TRIM KX 580 KX 480 KX 380 KX 480 KX 380 KX 580 PHONES LEVEL 1 3 STOP MPX FILTER indicator ŸB ŸC and ŸS KX 580 only indicators When a tape is loaded the corresponding tape type indicator lig...

Страница 6: ...layback Press the STOP button To fast forward the tape Press the button To fast rewind the tape Press the button To adjust the volume level Use the volume control of the amplifier or receiver To use headphones for private listening Insert the headphones plug into the PHONES jack To adjust the headphones level Use the PHONES LEVEL control DOLBY NR button setting in step 2 DOLBY NR OFF ŸB ŸC MPX but...

Страница 7: ...neously INTRO SCAN To play back the beginning of each selection automatically To play back each selection in the reverse direction The INTRO indicator lights during reverse intro scan 3 To play back each selection in the forward direction The INTRO indicator lights during forward intro scan To resume normal playback when the desired selection is found PLAY 5 Notes on Selection search and Intro sca...

Страница 8: ...ress the REPEAT OFF 0 M FULL button so that the REPEAT FULL indicator lights 3 REPEAT OFF 0 M FULL Note The length between the start and end points of the 0 M repeat section should be more than 4 counts To cancel repeat playback To cancel the 0 M repeat or Full repeat press the REPEAT OFF 0 M FULL button so that both REPEAT 0 M and REPEAT FULL indicators go off Each time this button is pressed rep...

Страница 9: ... only 2 REC indicator Tape counter MPX FILTER indicator PEAK level meters ŸB ŸC ŸS KX 580 only indicators EJECT REC PAUSE DOLBY NR DOLBY NR PLAY To stop recording Press the STOP button To stop recording temporarily Press the REC PAUSE button To resume recording press the PLAY button Tape counter and COUNTER RESET button Before starting recording press the RESET button to set the counter reading to...

Страница 10: ... seconds To perform the Auto Tape Tuning send the tape leader part forward and set the PLAY TRIM control and the BIAS ADJUST control to the center position before pressing the AUTO TAPE TUNING button When the Auto Tape Tuning is completed the TAPE TUNING indicator lights After completion of Auto Tape Tuning the tape automatically rewinds to the point where the Auto Tape Tuning began and the REC PA...

Страница 11: ...ding needs further bias adjustment to compensate for absent or distorted high frequencies adjust this control to your liking Output Level dB 10 0 10 20 30 40 1 2 3 Frequency Hz 1 Insufficient bias High frequencies are distorted 2 Optimum bias 3 Excessive bias High frequencies are absent When high frequencies are distorted increase the recording bias by turning the BIAS ADJUST control clockwise Whe...

Страница 12: ...TE SEARCH KX 580 only Tape counter Tape counter REC MUTE operation Inserting a blank space during recording A 4 second blank interval is automatically recorded on the tape and then the deck enters Rec Pause mode If a blank interval longer than 4 seconds is desired keep pressing the button as long as you want When the MUTE SEARCH button is released the deck enters Rec Pause mode after making a 4 se...

Страница 13: ...t time the timer will turn power on to the amplifier receiver and cassette deck and begin playback It will shut power off at the preset time as well ending playback Note Whenever the timer recording playback is not intended make sure to set the TIMER switch to OFF position to prevent the unnecessary recording playback If the TIMER switch is set to REC position and the power is supplied plugging in...

Страница 14: ...ack at the Normal Type I NORM settings which will result in an unnatural high frequency emphasis This effect may be compensated for somewhat by adjusting the BIAS ADJUST to the plus direction during recording or by using the PLAY TRIM tone control and or the tone controls of your amplifier receiver during playback PROTECTING YOUR RECORDINGS All cassette tapes are provided with erasure protection h...

Страница 15: ... will cause an accumulation of dirt and dust on the heads capstans and pinch rollers This can lead to poor sound quality drop outs intervals with no sound unsteady tape speed loss of high frequency response etc Thus clean the heads and all surfaces over which the tape travels with a commercially available cleaning cassette and fluid type cleaner DEMAGNETIZATION After 20 30 hours of use enough resi...

Страница 16: ...tape Blank sections must be at least 4 seconds long No remedy No remedy Play back in appropriate Dolby NR position Fault Tape doesn t move in recording or playback REC PAUSE button fails to function Sounds become faint and sometimes inaudible Recorded sound is distorted Tape is playing back but no sound is heard Excessive noise Excessive wow wavering of the sound Tape stops in the middle of record...

Страница 17: ...alloy Erase double gap Ferrite head Rapid Transport KX 580 480 90 sec C 60 KX 380 100 sec C 60 Wow and Flutter KX 580 480 WRMS 0 05 W Peak 0 08 KX 380 WRMS 0 07 W Peak 0 12 Signal to Noise Ratio KX 580 480 Dolby NR off 60 dB Dolby B NR on 68 dB Dolby C NR on 76 dB Dolby S NR on KX 580 only 80 dB KX 380 Dolby NR off 58 dB Dolby B NR on 66 dB Dolby C NR on 74 dB Frequency Response KX 580 480 Normal ...

Страница 18: ...TR 22 34 D 2084 RELLINGEN BEI HAMBURG F R OF GERMANY YAMAHA ELECTRONIQUE FRANCE S A 17 RUE DES CAMPANULES LOGNES 77321 MARNE LA VALLEE CEDEX 2 FRANCE YAMAHA ELECTRONICS UK LTD YAMAHA HOUSE 200 RICKMANSWORTH ROAD WATFORD HERTS WD1 7JS ENGLAND YAMAHA SCANDINAVIA A B J A WETTERGRENS GATA 1 BOX 30053 400 43 VASTRA FRÖLUNDA SWEDEN YAMAHA MUSIC AUSTRALIA PTY LTD 17 33 MARKET ST SOUTH MELBOURNE 3205 VIC ...

Отзывы: