14
KMA-1000/KMA-950
KMA-1000/KMA-950
CONFIRMATION OF IDLING CURRENT OF AMP UNIT
■
R429 (L ch)
R430
(R ch)
TP413–TP415 (L ch)
TP414–TP416 (R ch)
Open (cut off)
20 mV – 350mV
(DC)
R429
R430
TP416
TP414
TP415
TP413
Rear side
Front side
Item
Condition
Test point
Raiting
Remark
Idling current
No input signal
Wait for 2–3 minutes
TP413–TP415 (L ch)
DC 20–350mV
If measured voltage exceeds 350 mV,
open (cut off) R429 (L ch), R430 (R ch)
and reconfi rm the voltage.
TP414–TP416 (R ch)