background image

13 

13.

 

Exit the Dante Firmware Update Manager, and wait for two minutes before turning off the power to 

the device to which the HY144-D is installed. 

After recovery, restart the Dante module. If you power-off the device to which the HY144-D is installed before 

restart is completed, the data of the Dante module will be corrupted, and you will have to perform the recovery 

once again. Start Dante Controller, and if the device name is shown in black, it is safe to turn off the power.

   

 
14.

 

The correct Dante firmware now needs to be loaded. 

After recovery, the Dante firmware will not be the latest version. To update to the latest firmware, perform steps 2 

through 11 of "

Updating the Dante firmware

." 

At this time, also perform “Check the [Override Device Matching]” 

in step 7. 

 
Now recovery and firmware update are completed. 
 

Manual Development Group 

© 2018 Yamaha Corporation 

 

Published 02/2018 YJHH  -A0 

Содержание HY144-D

Страница 1: ...e again please contact your Yamaha dealer Yamaha Corporation owns exclusive copyrights for this update guide Audinate owns exclusive copyrights for the Dante firmware and its update program It is proh...

Страница 2: ...check the Dante firmware version number from the FIRMWARE VERSION screen of CS R10 CS R10 S CSD R7 RIVAGE PM Editor or Dante Firmware Update Manager of Audinate PM10 FIRMWARE VERSION screen of the MAI...

Страница 3: ...An Ethernet cable CAT5e or higher recommended Straight or cross The Dante firmware update program Download the latest program from the following URL https www yamaha com proaudio Update procedure seq...

Страница 4: ...te firmware extension dnt from the compressed file The Dante firmware will not work correctly if the path contains any characters other than single byte alphanumeric characters hyphen or _ underscore...

Страница 5: ...Change Adapter settings from the Tasks list located in the left side of Network and Sharing Center window then double click Local Area Connection The Local Area Connection Status dialog box will be di...

Страница 6: ...dialog box will be displayed 2 Click the service that you want to connect to the device If you re using the Ethernet port that s built into the Mac click Ethernet 3 In Configure IPv4 choose Using DHC...

Страница 7: ...right click and select Run as Administrator Mac Application Dante Firmware Update Manager then double click Dante Firmware Update Manager The Dante Firmware Update Manager will start up Check that th...

Страница 8: ...rmware from V3 8 1 4 or earlier to V3 10 4 1 or later Be sure to confirm the name of the update file to prevent updating with wrong files 8 Click Next In some cases the Windows firewall may be blockin...

Страница 9: ...ate takes 2 to 4 minutes During the update operation do not turn off the power to the unit or disconnect the cable If update fails due to disconnection of the power cable during the update or due to o...

Страница 10: ...fe mode To restore the Dante module from failsafe mode a recovery image must be sent from the Firmware Update Manager If the red ERROR indicator of the HY144 D is lit it may be that the Dante module i...

Страница 11: ...onnection 4 Turn on the power to the device to which the HY144 D is installed 5 Disable all but one of the network interfaces on your computer You should also disable the wireless LAN 6 Windows Select...

Страница 12: ...ther the TCP IP settings are correct or not and whether the device which is installed the HY144 D is running or not 10 Select the check box of the detected HY144 D 11 Click Start A pop up is displayed...

Страница 13: ...ave to perform the recovery once again Start Dante Controller and if the device name is shown in black it is safe to turn off the power 14 The correct Dante firmware now needs to be loaded After recov...