RX-V800/RX-V800RDS/HTR-5280
12
• Functions in DIAG mode
In addition to the DIAG menu items, functions as listed below are available.
• Input selection, 6CH input
• REC OUT (ZONE2) switching
• Center/Rear/Sub-woofer level adjustment
• Muting
• Speaker relay A/B
• Power on/off
• Master volume
It is possible to set to the following volume values directly by transmitting remote control codes during the DIAG operation
only.
Volume value (dB) Remove control
Remote control
code
key
0
7A-E0
PAGE A
-20
7A-E1
PAGE B
-30
7A-E2
PAGE C
MUTE
7A-E3
PAGE D
* Functions related to the tuner and the set menu are not available.
* It is possible to confirm Menu No.11 IF STATUS while keeping the signal process (operation status) of each DIAG menu
by using the input mode key of the main unit.
• Initial settings used to start DIAG
Following initial settings are used when starting DIAG.
When DIAG is canceled, these settings are restored to those before starting DIAG.
• Master volume: -40dB
• Input, ZONE2 input: DVD (6CH INPUT OFF)
• Center/Rear/Sub-woofer level: 0dB
• Audio mute: OFF
• Speaker relay A/B: ON
• Speaker setting: LARGE / BASS OUT = BOTH
• DIAG menu: DSP through (analog bypass)
Содержание HTR-5280 - AV Receiver - 5.1 Channel
Страница 75: ...RX V800 RX V800RDS HTR 5280 ...