RX-V395/RDS HTR5130/RDS
RX-V395/RDS
HTR5130/RDS
■
AMP ADJUSTMENTS
●
Confirmation of Idling Current
Right after Power is switched ON, confirm that the voltage across each resistor,
R-124, -127, -130, -136, and -143,is between 0.1mV to 5mV. If the voltage exceeds 5.2mV,
open (cut off) R-171, -177, -189, -195, -183 and confirm that the voltage becomes 0.1mV to 5mV.
R130
R177
MAIN (1)
R136
R143
R124
R127
R171
R189
R195
R183
12
R171(Lch),177(Rch)
R189(RLch),195(RRch),183(Cch)
R124(Lch),127(Rch)
R130(RLch),136(RRch),143(Cch)
3P 0.22
cut off