–31–
CLOCK
ELEC
Tester (+) read
Brow
Tester (–) read
Frame ground
1. Voltage
Connect the pocket tester (DC 20 V) to the
clock coupler.
Turn the main switch to “ON”.
Check the voltage (12 V) on the “Brown”
lead at the clock terminal.
The wiring circuit from the main switch to the
clock coupler is faulty, repair it.
MEETS
SPECIFICATION
OUT OF SPECIFICATION
1
This circuit is not faulty.
2. Clock
Check that the clock is operating properly.
When setting the clock after its power
source has been disconnected (e.g., when
the battery is removed), first set the clock to
1:00 AM and then to the correct time.
1
The clock is faulty, replace it.
MEETS
SPECIFICATION
OUT OF SPECIFICATION
CLOCK
EAS00805
The clock fails to come on.