TRBL
SHTG
Troubleshooting
9-9
67C3K11
Symptom 1: PTT unit does not hold the outboard motor up
Troubleshooting the lower unit
Symptom 1: Shift mechanism of the forward gear and reverse gear does not operate properly
Symptom 2
Cause 1
Cause 2
Checking step
Refer
to
page
—
Manual valve left
open
Manual valve mal-
function
Check the manual
valve.
Insufficient PTT
fluid
—
Add sufficient fluid.
PTT fluid leakage
—
Check the PTT unit
for leakage.
Air in PTT fluid
—
Bleed the PTT unit.
Clogged fluid pas-
sages
—
Disassemble and
check the PTT unit.
Malfunction of the
PTT unit internal
parts
Symptom 2
Cause 1
Cause 2
Checking step
Refer
to
page
—
Throttle open
—
Turn the throttle
grip or move the
throttle lever to the
fully closed position.
Shift cable and shift
cable joint malfunc-
tion
—
Check and adjust
the shift cable and
shift cable joint.
Remote control box
malfunction (R
model)
—
Check the remote
control box. (R
model)
Shift arm malfunc-
tion
—
Check the shift link
rod.
Detent malfunction
Check the shift arm.
Shift rod operation
malfunction
Shift rod not con-
nected correctly
Check the connec-
tion of the shift rod.
Shift rod not
adjusted correctly
Adjust the shift rod.
Shift mechanism
malfunction (in
lower unit)
—
Disassemble and
check the lower
unit.
Содержание F30A
Страница 1: ...F30A F40B SERVICE MANUAL 67C 28197 3K 11 ...
Страница 4: ......
Страница 26: ...GEN INFO General information 1 21 67C3K11 MEMO ...
Страница 150: ...POWR Power unit 5 55 67C3K11 MEMO ...
Страница 172: ...LOWR Lower unit 6 21 67C3K11 Shimming S67C6063 T1 T2 B2 A2 F R P T3 B3 A3 42 0 T1 T2 B1 28 0 28 0 B2 A2 A1 ...
Страница 236: ...BRKT Bracket unit 7 55 67C3K11 MEMO ...
Страница 282: ......
Страница 283: ...YAMAHA MOTOR CO LTD Printed in China Aug 2007 1 2 1 CR E ...