EMX5014C Owner’s Manual
32
Reference
Specifications
■
General Specifications
Output impedance of signal generator: 150 ohms
*
These specifications apply to rated power supplies of 120V, 230V and 240V
.
MIN
TYP
MAX UNIT
Maximum Output Power
(SPEAKERS)
(RL=4 ohms) Both ch drive, 1kHz, THD+N 0.5%
500
W
(RL=8 ohms)
350
(US,AU)
320
(EU)
Total Harmonic Distortion
(THD+N) 20 Hz-20 kHz
(ST, ST SUB, AUX, EFFECT) +14dBu output into 600 ohms
0.3
%
(REC) 0 dBV output into 10 kohms
0.5
%
Frequency Response
(ST, ST SUB, AUX, EFFECT) GAIN at minimum level, PAD=OFF, 20Hz-20kHz,
nominal output level @ 1kHz
–3.0
0.0
1.0
dB
(SPEAKERS)
–3.0
0.0
1.0
dB
EIN=Equivalent Input Noise
(ST OUT) GAIN at maximum level, 20Hz-20kHz
–128
dBu
Residual Output Noise
(SPEAKERS)
–68
dBu
(ST, ST SUB, AUX)
–95
dBu
Crosstalk @ 1kHz
adjacent inputs
–68
dB
input to output
–68
dB
Maximum Voltage Gain
@1kHz
CH MIC INPUT
→
SPEAKERS
109
dB
CH MIC INPUT
→
ST OUT
84
dB
CH MIC INPUT
→
AUX SEND (PRE), ST SUB
80
dB
CH MIC INPUT
→
AUX SEND (POST)
90
dB
CH MIC INPUT
→
EFFECT SEND
78
dB
CH MIC INPUT
→
REC OUT
62.2
dB
ST CH 11/12,13/14
→
ST OUT
58
dB
Phantom Voltage
(CHs 1-6, 7/8, 9/10) No load
48
V DC
Monaural/Stereo channel
Equalizer
± 15 dB (Maximum Variation)
Turn over/roll-off frequency of shelv-
ing, 3 dB below maximum variable
level.
HIGH 10kHz (shelving)
MID (MONO) 250-5kHz (peaking)
MID (ST) 2.5kHz (peaking)
LOW 100Hz (shelving)
PEAK Indicator
On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) comes within 3 dB of the clipping level.
SIGNAL Indicator
On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) reaches –10 dB.
FCL Indicator
Input signal level: –75dB
LEVEL meter
(ST, PFL/AFL) Two 12-points LED level meter (PEAK, +5, +3, +1,0, –1, –3, –5, –7, –10, –15,
–20 dB)
PEAK lights if the signal comes within 3 dB of the clipping level.
Graphic Equalizer
(ST OUT) 9 band (63, 125, 250, 500, 1k, 2k, 4k, 8k, 16 kHz) ±12 dB (Maximum Variation)
Internal Digital Effect
16 programs, Parameter control
Foot Switch (Internal Effect ON/OFF)
Power Amplifier Protection
POWER Switch on/off mute
DC-fault: power supply shutdown/manual reset
Thermal/heatsink temp 90˚C: output mute/auto reset
Vl limiter /RL 2 ohms
Clip limiter/THD 1 % , Indicator
×
2
Power Supply Protection
Thermal/heatsink temp 100˚C: power supply shutdown/manual reset
Cooling
Dual variable-speed fan
<
=
>
=
<
=
>
=
>
=
MIN
TYP
MAX UNIT
Power Consumption
500
W
AC Cord
Length
2500
mm
Dimensions
Height
155
mm
Depth
493
mm
Width
444
mm
Weight
10.5
kg