Battery charging
Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a special
(constant-voltage) battery charger is required.
TIP
9
The generator DC rated voltage is 12 V.
9
Start the engine first, and then connect the gener-
ator to the battery for charging.
9
Before starting to charge the battery, make sure
that the DC protector is pressed to “RESET”.
1. Start the engine.
NOTICE
2. Press in the DC protector.
1
“RESET”
2
“OFF”
3. Connect the red battery charger lead to the posi-
tive (+) battery terminal.
1
Red wire
2
Black wire
4. Connect the black battery charger lead to the neg-
ative (–) battery terminal.
5. Turn the economy control switch to “OFF” to start
battery charging.