4-9
–
+
ELEC
GENERATOR SYSTEM
GENERATOR SYSTEM
TROUBLESHOOTING CHART
WEAK OR NO AC CURRENT
Start the engine.
Check the overload warning light.
DOES NOT TURN ON
TURNS ON
Disconnect the overloaded electric device.
TURNS ON
DOES NOT TURN ON
Start the engine.
Check the AC output indicator.
TURNS ON
DOES NOT TURN ON
Replace the AC output indicator.
Rated engine speed inspection
Operate the engine with no load.
Set the economy switch to “OFF”.
3,550 r/min
GOOD
OUT OF SPECIFICATION
Check the throttle control system.
Refer to “THROTTLE CONTROL SYSTEM” in CHAP-
TER 3.
Main coil AC voltage inspection
Disconnect the sub coil coupler
1
.
Connect the Red and Green/Yellow leads, and then
connect the Orange leads.
Disconnect the main coil coupler.
Start the engine.
Connect the pocket tester to the Yellow leads.
Measure the voltage. (Tester range: AC 300 V)
Main coil AC voltage:
160 ~ 200 V
GOOD
TOO LOW
DOES NOT GENERATE
Or
Or
G/Y
G/Y
R
R
G/Y
R
Or
Or
Or
Or
1
SVU4150
Y
Y Y
Y
Y Y
SVU4160
*
Magnetic force is weak.
Replace the magneto rotor.
Main coil resistance measurement
Stop the engine.
Measure the resistance between the Yellow leads.
(Tester range:
Ω
× 1)
Main coil resistance:
0.6
Ω
± 20 % at 20°C (68°F)
GOOD
DISCONNECTED/
SHORT CIRCUIT
Replace the stator assembly.
Y
Y Y
SVU4170
Содержание EF2800i - Inverter Generator
Страница 1: ...SERVICE MANUAL EF2800i LIT 19616 00 92 7VU 28197 10 310115 ...
Страница 2: ......
Страница 8: ......
Страница 28: ......
Страница 101: ......