RX-V2300/DSP-AX2300
RX-V1300/RX-V1300RDS/HTR-5590/DSP-AX1300
RX-V2300/DSP-AX2300
RX-V1300/RX-V1300RDS/HTR-5590/DSP-AX1300
36
Initial display
初期表示
All segments OFF
全セグメント消灯
All segments ON (dimmer 100%)
全セグメント点灯(ディマー100%)
All segments ON (dimmer 50%)
全セグメント点灯(ディマー50%)
Lighting of segments
in lattice
セグメント格子状点灯
Lighting in lattice
格子状点灯
Normal
正常
Short
ショート
Segment conditions of the FL driver and the FL tube are
checked by turning ON and OFF all segments. Next,
the operation of the FL driver is checked by using the
dimmer control. Then a short between segments next
to each other is checked by turning ON and OFF all
segments alternately (in lattice). (In the above example,
the segments in the second row from the top are
shorted.)
9. EFFECT OFF / DISPLAY CHECK
This program is used to check the FL display section.
The display condition varies as shown below according
to the sub-menu operation. The signals are processed
using EFFECT OFF (The L/R signal is output using
ANALOG MAIN BYPASS.)
The video signal internal/external synchronization
switching is controlled by the microprocessor. When
the initial message is displayed and all the FL segments
light up, it is switched to the internal synchronization but
o t h e r t h a n t h a t i t i s f o r c e d t o t h e e x t e r n a l
synchronization setting.
Also, except for the initial display, 128 pictographs for
checking the OSD driver are used for the video signal
output display.
全セグメント消灯・全セグメント点灯によりFLドライ
バー、FL管のセグメントの不良を確認します。
次に、ディマーコントロールによってFLドライバーの
動作チェックを行います。
さらに全セグメントを交互(格子状)に点灯/消灯するこ
とで、隣り合うセグメントのショートをチェックしま
す。
9. EFFECT OFF / DISPLAY CHECK
FL表示部のチェックプログラムです。サブメニュー操
作により、表示状態が以下のように変わります。
信号処理はEFFECT OFF (ANALOG MAIN BYPASSで
L/Rを出力)です。マイコン制御による映像信号の内部/
外部同期切替は、初期表示とFL全点灯時に内部同期と
なり、それ以外は強制外部同期となります。
また、初期表示以外で映像出力にOSDドライバー確認
用128絵文字表示が出ます。