30
Principles of pedal maintenance
Pedal maintenance procedures for the Disklavier MK III Grand Piano are basically the same as for the
existing Disklavier II Grand Piano.
Sustain pedal
Shift pedal
1. Pedal cap nut adjustment
Adjustment for pedal cap nut (Acoustic adjustment)
Standard: 2mm (0.08 in) of space between damper lifting rail and damper levers
2. Lever stop button screw
adjustment
Adjustment for capstan button screw (Acoustic adjustment)
Standard: Damper felts are lifted off at 4-5mm (about 0.1in) from strings 1-2mm
(0.04-0.08in) of solenoid gap when the pedal is fully depressed.
3. Pedal measurement
Maintenance mode 03
4. Half point adjustment
Maintenance mode 03
Standard: Mute time = 1.5sec
5. Data parameter value manual
compensation
Maintenance mode 03
Normally not necessary
1. Pedal cap nut adjustment
Adjustment for pedal cap nut (acoustic adjustment)
Standard: No lost motion
2. Key block screw adjustment
Adjustment for key frame stop screw (acoustic adjustment)
3. Lever stop button screw
adjustment
Adjustment for capstan button screw (acoustic adjustment)
Standard: Lever stops as the same time the key frame quits moving.
* This screw is used only for the Disklavier II grand
4. Pedal measurement
Maintenance mode 04
5. Data parameter value manual
compensation
Maintenance mode 04
Normally not necessary
Содержание Disklavier DKC55RCD XG Mark III
Страница 50: ......