![Yamaha Crux S Скачать руководство пользователя страница 190](http://html.mh-extra.com/html/yamaha/crux-s/crux-s_workshop-manual_899518190.webp)
ELEC
R-189
7. RECTIFIER CUM REGULATOR UNIT
• Check the Charging Voltage
Procedure Steps
• Connect the Tachometer to Spark plug lead
• Connect the Multimeter ( DC 20V) to Bat-
tery Red Wire.
Measure the Battery Voltage : 12V
If less than specifications, charge the
Battery
• Start the engine and accelearte the Engine
up to 5000 RPM .
• Check the Charging voltage :
Charging voltage :
14 ~ 15 V at 5000RPM
Multimeter (+) lead Ÿ Battery (+) terminal ¿
Multimeter (-) lead Ÿ Battery (-) terminal À
MEETS SPECIFICATIONS
Charging Circuit and Rectifier cum Regula-
tor are OK
Rectifier cum Regulator unit is faulty.
• Replace RR unit
OUT OF
SPECIFICATION
8. WIRING CONNECTIONS
• Check the connection for entire Ignition and
Charging System “REFER TO CIRCUIT
DIAGRAM” Page 7-4
POOR CONNECTIONS
Repair/ Replace the Harness
9. CDI Unit
• Check CDI unit “REFER IGNITION
T I M I N G P R O C E D U R E C h a p t e r 3 ,
Page 3-11
IF CORRECT
IGNITION SYSTEM / CHARGING SYSTEM
7-8
æ