background image

 

How

 

to

 

confirm

 

the

 

installed

 

firmware

 

version

 

1.

 

Turn

 

on

 

the

 

instrument.

 

2.

 

Press

 

the

 

[FUNCTION]

 

button

 

several

 

times

 

to

 

select

 

“System”

 

menu.

 

 

3.

 

Press

 

[

]

 

button

 

several

 

times

 

to

 

select

 

“Utility”,

 

and

 

then

 

press

 

[

]

 

button.

 

  → 

 

4.

 

Press

 

[

]

 

button

 

several

 

times

 

to

 

select

 

“Version”,

 

and

 

then

 

press

 

[

]

 

button.

 

  → 

 

5.

 

Check

 

the

 

displayed

 

version

 

number.

 

 

Содержание CLAVINOVA CLP-635

Страница 1: ...gh free space 2 Use the list below to find the firmware file for your instrument and then copy it to the root of the USB flash drive file system Product Firmware File Name CLP 635 CLP 635SETUP PRG CLP 645 CLP 645SETUP PRG CLP 665GP CLP 665GPSETUP PRG CLP 675 CLP 675SETUP PRG CLP 685 CLP 685SETUP PRG CLP 695GP CLP 695GPSETUP PRG YDP 184 YDP 184SETUP PRG ...

Страница 2: ...located at the end of this document 1 Make sure that the instrument is turned off before updating the firmware 2 Insert the USB flash drive with the copied firmware into the USB TODEVICE terminal 3 Press and hold the ll PLAY PAUSE button and turn on the instrument Keep the ll button held down until the display shows the following message The red marking below shows where the ll button is located o...

Страница 3: ...inutes for big firmware data The display shows the installed version when the update completes 6 Turn off the instrument You can remove the USB flash drive 7 Press and hold the right most key C7 and turn on the instrument Notice This operation resets the instrument to its factor default settings Note that the Backup Setting will be reset to default This operation will not delete the User MIDI Song...

Страница 4: ...on the instrument 2 Press the FUNCTION button several times to select System menu 3 Press button several times to select Utility and then press button 4 Press button several times to select Version and then press button 5 Check the displayed version number ...

Страница 5: ...ror message is displayed and the installation aborts Follow the list below to check if The USB flash drive inserted correctly No dust or dirt is on the USB terminal The firmware data is placed in the root of the USB flash drive file system The USB flash drive data is corrupt or the USB f lash drive itself is broken The firmware data is the correct one for your instrument Using another USB flash dr...