TEST MODE
• Starting TEST mode
Test mode is started when the power is turned on while the “PLAY/PAUSE” and “STOP” keys on the panel are
simultaneously pressed and held.
When the test mode is started, as shown below is displayed.
Note:
“traverse servo” means the same as “feed servo”.
Panel key
Function
OPEN/CLOSE
PLAYXCHANGE
PLAY/PAUSE
STOP
T
T
T
T
T
SKIP
Y
Y
Y
Y
Y
SKIP
DISC 1
DISC 2
DISC 3
DISC 4
DISC 5
(Note 1)
Tray open/close.
Rotating the mode of coefficients. (Coefficient mode
→
Coefficient setting
→
Product mode) Pressing
twice will set to the product mode.
Plays if focus servo is effective. TRON, MUTE OFF.
All stop. (Focus, spindle, feed, laser, tray, etc..) Initializes FL display.
Backward traverse move. (If inner SW turns on, traverse is stopped.)
(Coefficient set up mode: upper digit down.)
Forward traverse move.
(Coefficient set up mode: upper digit up.)
Returns to product mode. (Tray and table inoperative.)
Adjustment mode 1 (TR-offset, FO-offset, FO-rough gain adjustment.)
Adjustment mode 2 (TR-balance, TR-rough gain adjustment.)
Adjustment mode 3 (FO-fine gain, TR-fine gain, FO-balance adjustment.)
Measure the rotating time of the table (rotate slow).
(Note 1) Measure the rotating time of the table (rotate fast/rotate slow).
1. Display for time mesurement.
The time display shows the time for 1 rotation of the table.
The unit of time is 0.1 second (rotate fast) or 1 second (rotate slow).
NOTE:
To fully operate all test modes the remote control must be used.
• Function List of Panel Keys
2. When the disc table is not positioned correctly, be sure to turn the disc table one full rotation by using the “DISC
SKIP
q
q
q
q
q
” or “DISC SKIP
w
w
w
w
w
” keys on the remote control unit before canceling the TEST mode.
"TEST" is displayed.
The firmware version of microprocessor and check sum value are displayed.
Starting TEST mode.
Clockwise
Counter clockwise