Make sure that the IP address specified for the Dante device IP address and the SLOT IP
are in the same subnet.
The following IP addresses cannot be used for the STATIC IP of the SLOT IP SETTING.
•
192.168.53.xxx /24
172.
17
.xxx.xxx /16 - 172.
24
.xxx.xxx/16
(These are reserved for RIVAGE PM systems.)
•
169.254.xxx.xxx /16 (Link-local addresses) *1
•
Multicast addresses
Use an IP address in a different subnet from the IP address used for the DSP ENGINE IP
SETTING.
To use multiple HY144-D/-SRC cards, specify the Dante Control ID. Set a unique ID to each
card (except for ID OFF).
AUTO IP + STATIC IP Setting
To connect two or more physically separate Dante networks, set one network to Auto IP to
create a link-local address and set the other network to Static IP by specifying a unique IP
address.