18
10. Main body specification
10.1 Main specifications
Type NDP-50FAN
Nominal Diameter
2” (50 mm)
Fluid
Connection
Suction Port
Rc 2 or Equivalent to JIS flange 10K50A
Discharge port
Air
Connection
Supply Port
Rc 3/4
Exhaust Port
Rc 1
Operating Air Pressure
0.2-0.7 MPa
Maximum Discharge Pressure
0.7 MPa
Discharge Volume/cycle
2400 mL
Maximum Discharge Volume
600 L/min
Maximum Air Consumption
7000 L/min(ANR)
Slurry
Limitation
Spherical
shape
φ
30 mm
or less
Stick shape
φ
15 mm×45 mm or less
Operating
Temperature
Range
Temperature
Ambient
0-70 °C
Temperature
Liquid
0-70 °C
A-weighted emission
sound pressure level
*2
94 dB
A-weighted sound power
level
*3
101 dB
Weight 52
kg
*1. Discharge Volume/cycle is highly dependent on application. Contact your local distributor or Yamada for
more information.
*2. The measuring method is based on ISO 1996.
*3. The measuring method is based on ISO 3744.