6. Method of cleaning
6. Method of cleaning
6. Method of cleaning
6. Method of cleaning
WARNING
WARNING
WARNING
WARNING
•Before starting operation, make sure that compressed air is not supplied to the pump.
•Before starting operation, make sure that the pump is not pressurized.
1)
Remove the hose from the suction side of the pump.
2)
Close the flow valve on the discharge side, open the drain valve, and then operate a pump by starting air
pressure for a while to discharge any fluid remaining inside the pump as much as possible.
3)
Remove the hose from the discharge side, and attach different hoses to the suction side and the discharge
side for cleaning.
4)
Be ready with a vessel with cleaning solution, select cleaning solution appropriate for the type of fluid
pumped, and then connect the suction-side and the discharge-side hoses of the pump.
5)
Operate a pump by starting air pressure slowly, and let the cleaning solution circulate for sufficient cleaning.
6)
Finally, flush with clean water.
7)
Remove the hose from the suction side of the pump, run the pump for a while and purge the pump of
remaining fluid as much as possible.
CAUTIO
CAUTIO
CAUTIO
CAUTION
N
N
N
•Be careful when removing piping. Fluid will gush out.
•After cleaning with clean water, turn the pump upside-down to drain out the water.
Содержание NDP-5 series
Страница 42: ...42 NDP NDP NDP NDP 25BF 25BF 25BF 25BF NDP NDP NDP NDP 25BP 25BP 25BP 25BP NDP NDP NDP NDP 25BV 25BV 25BV 25BV...
Страница 44: ...44 NDP NDP NDP NDP 40 40 40 40BP BP BP BP NDP NDP NDP NDP 40BV 40BV 40BV 40BV...
Страница 48: ...48 NDP NDP NDP NDP 80BF 80BF 80BF 80BF NDP NDP NDP NDP 80BP 80BP 80BP 80BP...
Страница 56: ...56 10 10 10 10 3 3 3 3 10 10 10 10 DP DP DP DP F F F F series series series series...