16
9. Retightening of Tie rods
(
only Fi/
□
/R
)
・
Since the dimensions of this pump may vary according
to the temperature or with the passage of time due to
the characteristics of its material: resin. Therefore,
check to see if any liquid material leaks at each sealed
portion periodically, and retighten the parts indicated
with arrow marks. [Fig.9-1]
・
The torque should be applied:
①
immediately before you use the pump,
②
during inspection to be performed every six months.
③
during inspection to be performed every year if you
use the pump in the clean room, that is, if the pump
is used within ± 5ºC of the temperature variation.
④
if the pump starts when the temperature of liquid
material is low: the temperature of this material
becomes high when the pump operates, and becomes
low when the pump stops.
⑤
if any leak of liquid or material is detected with the
daily inspection.
Retightening torque of the tie rods
DP
-
10Fi, DP
-
20Fi
5 N
・
m
Retightening torque of the valve cap
DP
-
10Fi, DP
-
20Fi
20 N
・
m
<
NOTE
>
-
Retighten the tie rod nut retainers on a diagonal
line with even force.
-
Be sure to retighten the valve cap with the
dedicated tool (see P.4).