IGNITION SYSTEM
19
SRM-2620ES, SRM-2620TES
T262XS, C262S
T262TXS, C262TS
3-4 Inspecting ignition switch
1. Disconnect primary lead coupler (A).
2. Disconnect ground lead coupler (B).
3. Connect one probe of Ohm-meter or multi-
meter to primary lead (C) of ignition switch side as
shown.
4. Connect the other probe to ground lead (D) of
ignition switch side as shown.
5. When ignition switch is in “RUN” position, tester
should indicate infi nite resistance.
6. When ignition switch is in “STOP” position, tes-
ter should show that the circuit is in conducting
state (closed circuit).
7. If ignition switch is defective, replace with a new
one.
A
B
C
D