YaliTech eti Скачать руководство пользователя страница 2

INSTRUMENT OPERATION

 

- Connect a 

probe via the socket located on the top 

of the instrument (where applicable). 

³ƬȸƺɯɎǝƺƬȒǼǼƏȸȒǔɎǝƺȵǼɖǕًˡȇǕƺȸٮɎǣǕǝɎ

to ensure a secure connection (do not 

over tighten).  The instrument is switched 

on by pressing the ON/OFF button. Apply 

the tip of the probe to the substance, 

medium or surface to be measured. The 

instrument reading may take a few seconds 

to stabilise, depending on the nature of the 

measurement and sensitivity of the probe.

HOLD

 

- Press the HOLD button to freeze the 

display.  Press again to continue measuring.

MAX/MIN

 

- Press the MAX/MIN button to 

display the values. The instrument retains the 

max/min values when switched off.  To reset, 

press the M

æٜxXz

 button for three seconds, 

'rst' will be displayed. 

AUTO-OFF 

- The unit will switch off 

automatically after 10 minutes. To disable 

auto off press the HOLD button whilst 

switching on the instrument (this is reset 

when the instrument is switched off).

TRIM - PRECISION, PRECISION PLUS & 

REFERENCE PLUS ONLY

 - 

Press the  

MAX/MIN and ON/OFF buttons at start-up 

ǔȒȸˡɮƺɀƺƬȒȇƳɀɎȒƺȇɎƺȸ٢…ǔǔɀƺɎǣɀƳǣɀȵǼƏɵƺƳ٣ِ

Press HOLD (up) or MAX/MIN (down) to set 

the trim value (maximum of ±2.00 °C). Press 

the ON/OFF button to save the value and exit 

Trim mode.

OPEN CIRCUIT/FAULTY PROBE 

- If the probe 

has developed an 'Open Circuit' fault the 

instrument will display 'Err'.

SENSORS

 

- This instrument should only be 

used with PT100 (platinum resistance probes, 

׎۳!ڻ׏׎׎׉٣ ³0zה׎וד׏ˡɎɎƺƳɯǣɎǝɀɖǣɎƏƫǼƺ

miniature plug (where applicable).

BATTERY REPLACEMENT

 

- The instrument 

ɯǣǼǼƳǣɀȵǼƏɵٔn… ÁٔɎȒɯƏȸȇɎǝƏɎɎǝƺƫƏɎɎƺȸǣƺɀ

will need changing soon. The instrument 

continues to measure accurately but after 

ǔɖȸɎǝƺȸɖɀƏǕƺɎǝƺǣȇɀɎȸɖȅƺȇɎɯǣǼǼƳǣɀȵǼƏɵٔˢƏɎ

bat' and shutdown. Replace the batteries with 

three AAA batteries located under the rear 

cover that is held in place by a single screw.

WARNING: 

IPA and other solvents may 

cause damage to the case and screen of 

this instrument.

GUARANTEE

 

- This instrument carries a 

two-year guarantee against defects in either 

components or workmanship. During this 

period, products that prove to be defective 

will, at the discretion of ETI, be either repaired 

or replaced without charge. This guarantee 

does not apply to probes, where a six-month 

period is offered. The product guarantee does 

not cover damage caused by fair wear and 

tear, abnormal storage conditions, incorrect 

use, accidental misuse, abuse, neglect, 

ȅǣɀƏȵȵǼǣƬƏɎǣȒȇȒȸȅȒƳǣˡƬƏɎǣȒȇِIɖǼǼƳƺɎƏǣǼɀ

of liability are available within ETI's Terms & 

Conditions of Sale at etiltd.com/terms.  In line 

with our policy of continuous development, 

we reserve the right to amend our product 

ɀȵƺƬǣˡƬƏɎǣȒȇɯǣɎǝȒɖɎȵȸǣȒȸȇȒɎǣƬƺِ

Отзывы: