background image

13

Unlocking the door from Outside (Touch key)

Open the lock using the Touch key from outside.

Contact the Touch key on [Key reader].

Unlocking the door from Inside

1. [Open/Close] button

Press the [Open/Close] button on the Back body in the lock
status to disable. Whenever you press [Open/Close] button,
the locks open and close function performs repeatedly.

2. Manual knob

Turn the [Manual knob] to 90 degree to
lock or disable.

Locked

Unlocked

Содержание YDR2105

Страница 1: ...Ver PMU 0808 01 ...

Страница 2: ... The function and design of this product may chang without notice User Manual YDR2105 ...

Страница 3: ...ations 7 How to use Registering security code 8 Registering keys 10 Deleting keys 11 Unlocking the door from Outside Security code 12 Unlocking the door from Outside Touch key Inside 13 Automatic Manual Lock mode 14 Beep mode 15 Error sound 16 Emergency mechanical key override 17 Damage alarm 18 Heat alarm 19 Battery 20 FAQ 21 ...

Страница 4: ...r product Please contact your nearest authorised service agent for any repairs or maintenance When cleaning use only a damp cloth to clean the lock body Note Do not use any chemicals when cleaning This product may be damaged by impact This could result in a malfunction ...

Страница 5: ...4 Basic contents Front Body Front Body Gasket YDR2105 Back Body Strike Strike packing plate Rotation resistant ring Touch keys 4 Mechanical key 2 Back Body Gasket Back body Bracket ...

Страница 6: ...5 Identification of Product 1 Front Body Keypad cover Emergency Power Supply Terminal Keypad LED Key reader Emergency override cylinder ...

Страница 7: ...6 2 Back Body Battery cover Auto Manual Lock switch Registration button Open close button Manual knob Automatic locking sensor Dead bolt ...

Страница 8: ...n be adjusted to suit the environment 7 The lock features a one touch lock unlock system 8 Power consumption A power saving circuit ensures long battery life 9 Damage alarm This product incorporates an alarm system that can trigger a sensor when the lock is subject to attack or force Product Specification Items Specifications Power AA type alkaline 1 5V Battery x 4 6v Emergency power 9V battery x ...

Страница 9: ...on button Inside 2 Enter your security code 3 Press button Caution When you register or change the security code check for correct operation with the door in the open position Open Battery Cover and Press the registration button Note sound The registration is completed with a sound Note sound Open Keypad Cover and enter the code you wish to register 4 12 digits Note sound ...

Страница 10: ... Security code operation Once registration is completed make sure to open the lock with your new security code while the door in the open position Caution It is recommended to change your pincode on a regular basis ...

Страница 11: ...s the registration button Inside 2 Touch key contact 3 Press button 4 Check the key operation Operating the lock with your Touch key to Key reader Open Battery Cover and Press the registration button Note sound Contact all the Touch keys you wish to register on the Key reader one by one Note sound ...

Страница 12: ...he registration button Inside 2 Press the button Open Battery cover and press the registration button Note sound Open Keypad Cover Press and hold the button for 5 seconds The deleting process ins completed with sound Note sound ...

Страница 13: ...e light on the keypad is on When the blue light turns off press button and try again If you want to cancel a security code due to the incorrect input please press button and then input the numbers again Caution If you fail to input the security code more than 5 times in succession you will hear a warning beep for 8 seconds the door lock will not work for 1 minute If you press the button to cancel ...

Страница 14: ... on Key reader Unlocking the door from Inside 1 Open Close button Press the Open Close button on the Back body in the lock status to disable Whenever you press Open Close button the locks open and close function performs repeatedly 2 Manual knob Turn the Manual knob to 90 degree to lock or disable Locked Unlocked ...

Страница 15: ...sition switch to manual Open the battery cover on the Back Body and set the automatic manual lock transition switch to automatic 2 Setting Automatic lock mode Automatic mode and Manual mode Automatic mode Door locks automatically when closed Note If batteries are discharged completely the auto locking function will note operate Manual mode When closed the door remains unlocked Press the Open close...

Страница 16: ...he Keypad cover up Enter your registered security code then press button You can control the volume sound Higher volume press 3 Lower volume press 6 Press button Caution Beep mode is a factory default setting When you use Volume control function door lock should be locked position You can control the volume up to 8 level ...

Страница 17: ...t the end of this warning period 1 Press the Open Close button on the Back body The system will resume normal operation after 1 minute 2 Enter the security code 3 Contact the key If the keypad cover is open for more than 5 times without using the security code or key you will hear a sound every 8 seconds and continuous beep will be audible at the end of this warning period The system then will res...

Страница 18: ...17 Emergency mechanical key override Use the emergency key to lock or unlock the door If you forget the security code If battery power is depleted ...

Страница 19: ...the registered key or input the security code then press button to unlock the door A sensor will detect force or impact and trigger a continuous warning beep alarm for 5 minutes Note sound 2 minutes Open the battery cover on the Back Body and either remove the batteries or press the registration button Indoor ...

Страница 20: ...ree Celsius 140 degrees Fahrenheit The detection temperature can be different depending on the installation circumstance Caution If the sensor is exposed to the direct ray of sun light for a long time it will trigger the heat alarm The heat alarm can be turned off by removing batteries or press open close button ...

Страница 21: ... placing a 9v battery on the external power source to power the lock then operate as usual using the Touch key or keypad Operating temperature range 20 55 C Operating voltage range DC4 5V DC6V LRT 1 5V AA sizex4 Cautions Batteries must be alkaline When batteries are discharged completely it is necessary to replace all Never mix new and old or batteries If you insert batteries in incorrect or wrong...

Страница 22: ...ing function does not operate Make sure that Automatic Manual transition switch is set to the Automatic locking position Open the door and Press the open sensor to activate the dead bolt to verify the operation with the door open Ensure the batteries are fully charged The door does not lock when closed Check the bolt function and striker alignment The lock will not power up Ensure all batteries ar...