80-9303-2214-010 (07-08)

Right Hand Door

Left Hand Door

Preload

Pinion Flat

Preload

S

Pinion Flat

S

Top-Jamb Installation                                                                    Figure 5

9/32” (7 mm);
3/8” (9.5 mm) dia. x
3/8” (9.5 mm) deep on
door opposite to closer

Standard

Optional

Through-bolts and
grommet-nuts

All

Preparation for Fasteners

Door or Frame

Fasteners

Drill-Sizes

Self-Drilling Screw

Wood

3/16” (4.30 mm)

1/4” - 20 machine screw

Metal

Drill: #7 (0.201” dia.)
Tap: 1/4” - 20

Sleeve nuts and bolts

Hollow

Metal

9/32” (7 mm) through;
3/8” (9.5 mm) door face
opposite to closer

Aluminum

or Wood

3/8” (9.5 mm) through

Aluminum

or Metal

No drill required

Installation Sequence

• Set average-power of multi-size closer. (Series UNI

TJ3301, UNI TJ3501 ONLY) See Power Adjust chart
on Page 1.

• See Figure 2 or 3 and select template dimensions.

Note: Separate template required for other
applications.

1-3/4" (44mm) thick door on 4-

1/2" (114mm) wide hinges or 3/4" (19mm) offset-
pivots.

1-3/4" (44mm) thick door on center-

pivots. Frame reveals and door opening angles as
charted; shock absorber will permit five (5) degrees of
door travel beyond hold-open position.

• Locate holes on frame face, stop-side. Four (4) for

closer (or drop plate).

• Locate holes on door. Two (2) for arm-foot.

• Prepare door and frame for fasteners. See chart

"Preparation for Fasteners" (Figure 4). Note: Use of
sex-nuts is recommended for fastening arm foot to
door and the closer body to a flush transom.

Figure 2:

Figure 3:

• Mount drop plate, (if used) and closer. Closer power

adjustment shaft toward lock edge.

• Disassemble rod-unit from arm-assembly and install

on door. Rod under shock-absorber and closest
possible to lock edge (See Figures 1 and 5).• Mount
main arm onto closer pinion shaft, aligning proper arm
mark with pinion flat. Secure with main arm screw.
Arm Mark "S" (See Figure 5).

• Insert connecting rod into slide unit and preload arm.

Secure with rod screws. Adjust rod to perpendicular
with door. See Figure 5.

• Adjust closer and install cover. See "Unit Adjustment"

on back page.

Figure 4

Содержание UNI Series

Страница 1: ...re that door swing five 5 degrees past hold open point to dead stop position It is suggested that sex nuts and bolts be used to mount arm foot and to mount closer to flush partitions Top Jamb Unitrols are supplied with arm rod units according to frame reveal An arm number is stamped on the arm rods as shown on Figures 2 and 3 page 2 UNI Stop Holder The closing force for these series door closers i...

Страница 2: ...offset pivots Figure 2 A rm N umber Stamp J6600 4 J6600 7 J6200 4 J6200 7 J6100 4 J6100 7 J6400 4 J6400 7 0 3 8 0 10 2 1 2 3 1 4 55 83 Dimension A 1 2 2 13 50 Dimension A Dimension A 3 3 8 4 1 4 85 108 Dimension A 5 1 2 6 3 8 140 162 Dimension A J6500 41 J6500 71 4 3 8 5 3 8 111 137 Dimension A Reveal Door Opening Angle J6500 43 J6500 73 6 1 2 7 3 8 165 187 Dimension A J6400 42 J6400 72 Figure 3 A...

Страница 3: ... 3 4 19mm offset pivots 1 3 4 44mm thick door on center pivots Frame reveals and door opening angles as charted shock absorber will permit five 5 degrees of door travel beyond hold open position Locate holes on frame face stop side Four 4 for closer or drop plate Locate holes on door Two 2 for arm foot Prepare door and frame for fasteners See chart Preparation for Fasteners Figure 4 Note Use of se...

Страница 4: ...r using screws provided controls are at arm elbow models suffixed H To select hold open on or hold open off and to adjust the hold open force Use screwdriver as illustrated Hold Open See Figure 10 80 9303 2214 010 07 08 Closing Speed Hydraulic Control Figure 8 Fig 7B Fig 7A 1 8 Hex Key 1 8 Hex Key Backcheck Figure 9 1 8 Hex Key Increase Decrease Backcheck Valve NEVER close this valve completely Sl...

Отзывы: