Yale UNI Series Скачать руководство пользователя страница 1

Installation Instructions

80-9303-2214-010 (07-08)

Components:

3300 Series Standard

Narrow Plastic Cover

w/ 1639 Pinion Cap

3500 Series

Standard Plastic

Cover with Insert

Optional

Full Metal Cover

with Cover Screws

3500M Series

Optional Architectural

Metal Cover

3500MA Series

Optional

Architectural Plastic

Full Cover w/ Insert

3500A Series

Power
Adjustment
Shaft

2 Sex-nuts

Rod Unit

(Arm Number Stamp)

Main Arm

Screw

Rod Screws

Slide unit

Holder Control

S

Optional

Thru-Bolt

&

Grommet Nuts

An incorrectly installed or improperly

adjusted door closer can cause property

damage or personal injury. These instructions

should be followed to avoid the possibility

of misapplication or misadjustment.

CAUTION

!

!

!

!

Always use template covering door-opening-angle desired,
correct door-thickness and frame-reveal, and door-hanging-
hardware being used. Template dimensions in these
instructions (page 2) cover frame reveals to 7-3/8” (187mm)
in opening with 1-3/4” (44mm) thick doors hung on 4-1/2”
(114mm) wide template-hinges (figure 2), 3/4” (19mm)
offset-pivots (figure 2) or center-pivots (figure 3).

Check hand of door: right or left (see figure 5, page 3). Make
sure that door opens the full angle desired and latches
without any binding action or interference. Note that hold-
open units will require that door swing five (5) degrees past
hold-open point, to dead-stop position.

It is suggested that sex-nuts and bolts be used to mount
arm-foot and to mount closer to flush partitions.

Top Jamb Unitrols are supplied with arm rod units according
to frame-reveal. An arm number is stamped on the arm
rods, as shown on Figures 2 and 3 (page 2).

UNI Stop/Holder

The closing force for these series door
closers is adjustable from a size 1 to a size 6,
as outlined in ANSI Standard A156.4. When
these series of door closers are installed and
adjusted to conform to ADA reduced opening
force requirements (5 lbs max.) for interior
doors, they may not have adequate closing

force to reliably close and latch the door. Power adjustments
charted on Page 4 are recommended where possible, to
ensure proper door control.

Power Adjustment Chart for TJ3301/TJ3501, TJ3311/TJ3511 ONLY

NOTE: Maximum of 20 turns (360°) of Power Adjustment Shaft.

Closer is shipped set at 10 turns.

4

7

8

9

7

8

10

12

Interior

Door

Exterior

Door

DOOR

32”

(0.85M)

36”

(0.90M)

42”

(1.00M)

48”

(1.20M)

MAXIMUM DOOR SIZE

Number of Turns Required

is identified with a "DL" suffix to the series number.

Multi-Size 1 thru 6

2, 3, 4, 5 or 6

Multi-Size 1 thru 6

Series No.*

UNI TJ3301
UNI TJ3500
UNI TJ3501

UNI TJ3311
UNI TJ3510
UNI TJ3511

* These series have a DELAYED ACTION CLOSING option available that

Non Hold Open

Hold Open

Sizing

UNI TJ3300

2, 3, 4, 5 or 6

UNI TJ3310

Power Adjust

Use 5/16” Socket or Adjustable Wrench

for this Adjustment

+

-

Содержание UNI Series

Страница 1: ...re that door swing five 5 degrees past hold open point to dead stop position It is suggested that sex nuts and bolts be used to mount arm foot and to mount closer to flush partitions Top Jamb Unitrols are supplied with arm rod units according to frame reveal An arm number is stamped on the arm rods as shown on Figures 2 and 3 page 2 UNI Stop Holder The closing force for these series door closers i...

Страница 2: ...offset pivots Figure 2 A rm N umber Stamp J6600 4 J6600 7 J6200 4 J6200 7 J6100 4 J6100 7 J6400 4 J6400 7 0 3 8 0 10 2 1 2 3 1 4 55 83 Dimension A 1 2 2 13 50 Dimension A Dimension A 3 3 8 4 1 4 85 108 Dimension A 5 1 2 6 3 8 140 162 Dimension A J6500 41 J6500 71 4 3 8 5 3 8 111 137 Dimension A Reveal Door Opening Angle J6500 43 J6500 73 6 1 2 7 3 8 165 187 Dimension A J6400 42 J6400 72 Figure 3 A...

Страница 3: ... 3 4 19mm offset pivots 1 3 4 44mm thick door on center pivots Frame reveals and door opening angles as charted shock absorber will permit five 5 degrees of door travel beyond hold open position Locate holes on frame face stop side Four 4 for closer or drop plate Locate holes on door Two 2 for arm foot Prepare door and frame for fasteners See chart Preparation for Fasteners Figure 4 Note Use of se...

Страница 4: ...r using screws provided controls are at arm elbow models suffixed H To select hold open on or hold open off and to adjust the hold open force Use screwdriver as illustrated Hold Open See Figure 10 80 9303 2214 010 07 08 Closing Speed Hydraulic Control Figure 8 Fig 7B Fig 7A 1 8 Hex Key 1 8 Hex Key Backcheck Figure 9 1 8 Hex Key Increase Decrease Backcheck Valve NEVER close this valve completely Sl...

Отзывы: