Yale SDA16 Скачать руководство пользователя страница 6

An ASSA ABLOY Group brand

80-9470-0330-000 (01-13)

6



Alarm will not sound

Alarm sounds when keyswitch
is activated.

Alarm chirps every 10 seconds.

ARMED indicator LED, wrong
color.

Problem

TROUBLESHOOTING

Battery is not connected.
Battery needs replacing.
Alarm is not ARMED. Turn key clockwise.

Magnet Sensor is not installed correctly. Verify
that the proper handing applies (See Step 3, Figure 5).

Tamper Switch is not closing when Alarm Housing
is installed. Make sure Switch Contact is located in the
correct position (See Step 3, Figure 6). Verify that the 
Alarm Housing is installed correctly.

J2 connector not installed, or loose.

Low battery indicator, replace battery.

Change position of DS-5 Dip Switch.
“OFF” for RED ARMED indicator.
“ON” for GREEN ARMED indicator.

Solution

Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their

respective owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication. 

Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials.

Copyright © 

 Yale Security Inc., an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

2005, 2013

Product Support Tel 800.

 • www.yalelocks.com

810.WIRE (9473)

Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.

Содержание SDA16

Страница 1: ...SDA16 Stand Alone Alarm Device Installation Instructions An ASSA ABLOY Group brand 80 9470 0330 000 01 13 EMERGENCY EXIT ALARM WILL SOUND ...

Страница 2: ...Install Magnet to door frame with 2 4 screws supplied 1 For installation on an Out swinging Door mark a Vertical Reference Line 2 3 16 56mm off of the Frame Stop also decide the vertical placement on the door and mark a Horizontal Reference Line Fold template as shown and align with Vertical and Horizontal Reference Lines 2 Use a center punch to mark door for 2 144 3 7mm Dia 27 Drill mounting hole...

Страница 3: ...l secure NOTE Actuator should be free to rotate by installing in position shown Orient Arrow towards Door Edge 1 Remove 2 screws retaining the magnet sensor and set components aside 2 Remove 2 screws retaining the Tamper Switch and exchange locations of both components See Figure 5 3 Reattach components with the screws NOTE a The arrow on the magnet sensor should face outward towards the edge of t...

Страница 4: ...itor both doors TIP Attach unit to a wall stud 1c Wall Mounting to a single Gang Box Attach the Mounting Base through holes A and X using standard gang box screws as shown in Figure 8 Gang Box screws not provided Attach Alarm Housing per section 4 2 4 3 Standard Installation Hole D Hole D Hole X Gang Box Only Hole A 1 After preparing the door attach the Mounting Base to door through holes A D usin...

Страница 5: ...S 4 Reset Time Off Off 2 Minutes Off On 5 Minutes On Off 10 Minutes On On No Auto Reset every 30 seconds instead of RED to indicate a violation has occurred Armed and Violation LED Color Selection TABLE 3 Device is shipped standard per Table 3 so that RED LED flashes every 30 seconds when device is ARMED and flashes GREEN every 30 seconds under auto reset when door has been violated When the devic...

Страница 6: ...of DS 5 Dip Switch OFF for RED ARMED indicator ON for GREEN ARMED indicator Solution Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company Other products brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only These materials are protected under U S copyright laws All contents current at time of publi...

Страница 7: ...5 16 50 Magnet and Cylinder located on same centerline Arrow on Magnet oriented towards Alarm Housing Assembly L C DOOR Locate off of edge to clear swing of door L C CAUTION Office copiers and facsimile mach ines may change the size of a drawing and make the template inaccurate to use as a door marker If this is not the original template packed with the trim use only the holes on the door do not u...

Страница 8: ...stall Hardwire Option Std Install x Outside Cylinder FUNCTION A D E A C D E A B D E Dia 27 Drill 144 4 1 9 16 40 3 3 4 95 3 8 10 2x 099 3 Dia 39 Drill 13 16 21 1 21 32 42 2 3 16 56 2 3 16 56 1 25 Dia 1 1 4 32 Dia Thru 13 16 21 Dia 27 Drill 144 4 13 16 21 3 8 10 099 3 Dia 39 Drill 2x 1 21 32 42 2 3 16 56 3 16 5 Ref 1 16 2 Magnet and Cylinder located on same centerline Arrow on Magnet oriented away ...