Yale SCP400 Series Скачать руководство пользователя страница 3

L

R

Y

S

Z

Installation Sequence (Con’t)

Page 3

!

Mount closer on door.

Power

Adjustment Nut

DOWN

Left Hand Door

UP

Right Hand Door

(A drop plate is available for

use on doors having narrow top rails)

should be away from hinge. Valves

are

for

. Valves are

for

.

!

Use 1/8” hex wrench to close valves. Turn Clockwise.
For

, close valves ‘S/D’ and ‘L’.

, close valves ‘S’ and ‘L’.

STANDARD CLOSER

DELAYED ACTION CLOSER

!

With door closed, use wrench to rotate pinion shaft
as illustrated below.

Caution: Closer arm is under spring tension and
may be difficult to rotate.

Start (wrench) here

Rotate

Install arm here

!

Place main arm on shaft,

aligning mark on arm with

pinion flat on pinion shaft; “Z” for Left Hand Door; “Y”
for Right Hand Door. Secure with 1/4-20 x 1/2 (13)
round head machine screw with lock washer.

80-9344-0621-010 (06-09)

Main Arm Screw with Lock Washer

!
!

Reopen valves closed in Step 2. Turn
Counterclockwise
With door closed, align soffit plate with mounting
holes in frame. Fasten soffit plate to frame with flat
head screws provided.

CAUTION!

DO NOT BACK VALVES OUT OF
CLOSER OR A LEAK WILL RESULT

!

Install Cover:
Security closers only,

(SCP400/SCP4400) Install

cover bracket to closer body. (See Illustration below).
Fasten bracket with 2 #8-32 x 5/16 RHMS screws
provided.

Fasten cover to closer and cover bracket with 4 #8-
32x1/4 round head screws provided.

Bracket must
extend
underneath
tube

Содержание SCP400 Series

Страница 1: ... 6 t Push Side Installation Closer mounts on opposite to hinge push side of door Right Hand Door RH Left Hand Reverse LHR Hinge Edge of Door Left Hand Door LH Right Hand Reverse RHR Security Door Closers only Door closer cover is handed and cannot be reversed All other components are non handed It is recommended that the door on which the door closer will be installed be hung on ball bearing hinge...

Страница 2: ...or Size mm inches Full Clockwise Turns of Closer Power Adjustment Nut SCP4400 ONLY Interior Door Exterior Door 28 32 0 7 0 8 33 36 0 85 0 9 37 42 0 95 1 05 42 48 1 1 1 2 Closer is shipped set at median power setting 0 2 5 8 2 5 8 11 Do Not Scale Drawing Left Hand Door Shown Dimensions are in inches mm Maximum Door Swing 180 conditions permitting NOTE Maximum of 15 360 turns of Power Adjustment Nut...

Страница 3: ... Place main arm on shaft aligning mark on arm with pinion flat on pinion shaft Z for Left Hand Door Y for Right Hand Door Secure with 1 4 20 x 1 2 13 round head machine screw with lock washer 80 9344 0621 010 06 09 Main Arm Screw with Lock Washer Reopen valves closed in Step 2 Turn Counterclockwise With door closed align soffit plate with mounting holes in frame Fasten soffit plate to frame with f...

Страница 4: ... D Controls Delay Range Valve S Controls Sweep Range Valve L Controls Latch Range 1 8 Hex Key Slow Fast 1 8 Hex Key Increase Decrease Standard S D Sweep L Latch Delayed Action S D Delayed Action S Sweep L Latch 1 8 Hex Key B NEVER Close Completely 1 8 Hex Key Increase Decrease Open for backcheck later in door opening cycle Backcheck Position P Normally Closed Backcheck Cushion Power Adjustment Nut...