
Product diagram
Battery installation
The battery compartment is located on the rear of the alarm unit. It can be
accessed by removing the screw from the back of the unit and lifting the
cover.
Insert 4 ‘AA’ Alkaline size batteries (not included) as shown on the diagram
inside the compartment. When the final batteries are inserted the centre
red LED will flash 3 times. Replace the back cover and fix with screw.
NOTE:
Please wait 30 seconds before inserting new batteries whenever
you take old batteries out.
Setting the PIN code
In order to use the unit you must set a 4 digit PIN code, using the
buttons 1, 2, 3, Yale. The default setting of this is 1, 2, 3, Yale. To
change this;
1.
Enter the current PIN (default set to 1, 2, 3, Yale)
2.
Press CLR (the orange LED will be on for 3 seconds)
3.
Enter the new PIN code
4.
Enter old PIN and press CLR.
5.
The orange LED will flash 3 times to confirm
6.
The unit will return to disarm mode (red LED will flash 3 times)
NOTE:
For security reasons, if a delay of more than 5 seconds occurs
between any of the above steps all LEDs will flash 3 times, and the
unit will beep to confirm an error the unit will return to disarm mode.
NOTE:
If this procedure is not completed correctly within 5 attempts
the unit will lock for 5 minutes.
Installing the unit
The unit has been designed to be either free standing or wall
mounted.
To wall mount;
1.
Place the alarm in the desired location (preferably with the PIR
angled towards a door).
Operation
Leaving the protected area
Press the ARM button on the unit, the red LED will quickly flash to
confirm the unit is armed. You have 20 seconds to vacate the area.
During this period, 4 count down beeps (with 4 single Green LED
flashes) will sound to warn of the exit period.
Entering the protected area
Within 10 seconds of entering type in your 4 digit PIN code and press
CLR. The red LED will quickly flash and the unit will beep once to
confirm the unit is disarmed.
NOTE:
If PIN entered incorrectly 5 times, unit will beep 10 times and
the unit will ‘lock’ (not do anything e.g. keypad locked) for 5 minutes.
Unit continues in whatever mode it was in prior (e.g. siren sounding)
Alarm activated
If the unit is activated the siren will sound for 2 minutes. The orange
LED will also flash (this is to show which unit has been triggered, if you
have move than one device set up to work together).
Back
1.
Front ‘eyebrow’ contacts
2.
Motion sensor
3.
LED x 3
4.
ARM & CLR buttons
5.
1, 2, 3 & Yale buttons
6.
Siren
1
2
3
ARM
CLR
Front
1.
Reset button
2.
Battery compartment
3.
Rear contact points
Care and maintenance
To clean the unit, simply use a soft, slightly damp with water, cloth
and wipe dry immediately.
Caution: Never use chemicals to clean the unit as this may cause
damage to the plastic and result in the alarm not functioning.
Pairing the PIR with another unit from the
range
The standalone alarm range has been designed specifically to
operate as single units or be paired together to work as kits.
Up to 3 of the master units – those that have sensors as well as
sirens – can be paired together. The number of slave units – those
that do not have sensors – that will work together is limitless.
This PIR is a master unit.
Each master unit has a unique radio code, which can be sent to any
other unit in order to make them work together.
The procedure for doing this is as follows:
1.
Starting with any master unit which you want to be the main
unit for the system
2.
Enter your PIN code and then press the Yale button
3.
The LED will flash in the sequence green, orange, red
4.
The unit is now in ‘sending’ mode for the next 2 minutes.
The green and orange LED will flash every second
5.
Hold the rear metal contact points of the main unit against
the ‘eyebrow’ contact points of the learner unit to which you are
pairing
6.
To confirm the units are paired, the learner unit will have red LED
on constantly (indicates units in contact) and will beep once.
If you do not hear a beep
release the units and pair
again (step 5).
7.
Repeat this contact
(steps 5 and 6) for all
other learner units you
want to pair with the
main unit
8.
After the 2 minutes
sending mode the
main unit will return to
disarmed mode. The red
LED will flash 3 times to
confirm.
NOTE:
If you wish to exit the learning mode within the 2 minute
duration, press CLR button twice on the main unit to exit.
RANGE:
Minimum 1 metre, maximum upto 25 metres.
1
2
3