Yale SAA8011 Скачать руководство пользователя страница 2

Product diagram

Battery installation

The battery compartment is located on the rear of the alarm unit. It can be 
accessed by removing the screw from the back of the unit and lifting the 
cover.
Insert 4 ‘AA’ Alkaline size batteries (not included) as shown on the diagram 
inside the compartment. When the final batteries are inserted the centre 
red LED will flash 3 times. Replace the back cover and fix with screw.

NOTE:

  Please wait 30 seconds before inserting new batteries whenever 

you take old batteries out.

Setting the PIN code

In order to use the unit you must set a 4 digit PIN code, using the 
buttons 1, 2, 3, Yale. The default setting of this is 1, 2, 3, Yale. To 
change this;

1.

 Enter the current PIN (default set to 1, 2, 3, Yale)

2.

 Press CLR (the orange LED will be on for 3 seconds)

3.

 Enter the new PIN code

4.

 Enter old PIN and press CLR.

5. 

The orange LED will flash 3 times to confirm

6.

 The unit will return to disarm mode (red LED will flash 3 times)

NOTE:

 For security reasons, if a delay of more than 5 seconds occurs 

between any of the above steps all LEDs will flash 3 times, and the 
unit will beep to confirm an error the unit will return to disarm mode.

NOTE:

 If this procedure is not completed correctly within 5 attempts 

the unit will lock for 5 minutes.

Installing the unit

The  unit  has  been  designed  to  be  either  free  standing  or  wall 
mounted.
To wall mount;

1.

  Place  the  alarm  in  the  desired  location  (preferably  with  the  PIR 

angled towards a door).

Operation

Leaving the protected area

Press the ARM button on the unit, the red LED will quickly flash to 
confirm the unit is armed. You have 20 seconds to vacate the area. 
During  this  period,  4  count  down  beeps  (with  4  single  Green  LED 
flashes) will sound to warn of the exit period.

Entering the protected area

Within 10 seconds of entering type in your 4 digit PIN code and press 
CLR.  The red LED will quickly flash and the unit will beep once to 
confirm the unit is disarmed.

NOTE:

 If PIN entered incorrectly 5 times, unit will beep 10 times and 

the unit will ‘lock’ (not do anything e.g. keypad locked) for 5 minutes.  
Unit continues in whatever mode it was in prior (e.g. siren sounding)

Alarm activated

If the unit is activated the siren will sound for 2 minutes.  The orange 
LED will also flash (this is to show which unit has been triggered, if you 
have move than one device set up to work together).

Back

1.

 Front ‘eyebrow’ contacts 

2.

 Motion sensor   

3.

 LED x 3 

 

 

4.

 ARM & CLR buttons

5.

 1, 2, 3 & Yale buttons

6.

 Siren

1

2

3

ARM

CLR

Front

1.

 Reset button

2.

 Battery compartment

3.

 Rear contact points

Care and maintenance

To clean the unit, simply use a soft, slightly damp with water, cloth 
and wipe dry immediately.
Caution: Never use chemicals to clean the unit as this may cause 
damage to the plastic and result in the alarm not functioning.

Pairing  the  PIR  with  another  unit  from  the 

range

The  standalone  alarm  range  has  been  designed  specifically  to 
operate as single units or be paired together to work as kits.
Up to 3 of the master units – those that have sensors as well as 
sirens – can be paired together.  The number of slave units – those 
that do not have sensors – that will work together is limitless. 

This PIR is a master unit.

Each master unit has a unique radio code, which can be sent to any 
other unit in order to make them work together.  

The procedure for doing this is as follows:

1.

  Starting with any master unit which you want to be the main  

  unit for the system

2.

  Enter your PIN code and then press the Yale button

3.

  The LED will flash in the sequence green, orange, red

4.

  The unit is now in ‘sending’ mode for the next 2 minutes. 

  The green and orange LED will flash every second

5.

  Hold the rear metal contact points of the main unit against  

  the ‘eyebrow’ contact points of the learner unit to which you are  
  pairing

6.

 To confirm the units are paired, the learner unit will have red LED  

  on constantly (indicates units in contact) and will beep once. 
  If you do not hear a beep  
  release the units and pair  
  again (step 5).

7.  

Repeat this contact  

  (steps 5 and 6) for all  
  other learner units you  
  want to pair with the  
  main unit

8.  

After the 2 minutes   

  sending mode the    
  main unit will return to  
  disarmed mode. The red  
  LED will flash 3 times to  
  confirm.

NOTE:

 If you wish to exit the learning mode within the 2 minute 

duration, press CLR button twice on the main unit to exit.

RANGE:

 Minimum 1 metre, maximum upto 25 metres.