TROUBLESHOOTING PROCEDURES FOR RH702
Issue
Cause
What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON.
1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The wires on rotary switch are loose.
3. Make sure the wires on the switch are
connected properly.
4. The switch is defective.
4. Change the switch.
Light works, but
blower is not
turning.
1. The blower is defective, possible seized.
1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor.
3. Change the capacitor.
4. The blower wire is not connected.
4. Make sure the blower wire is plugged into the
molex connector.
The unit is
vibrating.
1. The blower is not secure in place.
1. Tighten the blower in place.
2. Damaged blower wheel.
2. Change the blower.
3. The hood is not secured in place.
3. Check the installation of the hood.
The blower is
working, but the
lights are not.
1. The light bulb plug is disconnected.
1. Check the light bulb plug connection.
2. Defective halogen bulb.
2. Change the halogen bulb.
3. The light bulb is loose.
3. Tighten the light bulb.
4. The wires on the switch are loose.
4. Make sure the wires on switch are connected
properly.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 26” and 36”
range.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors to eliminate
the outside wind fl ow.
3. Blockage in the duct opening or duct work.
3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind.
4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
5. Change the ducting to correct size.
Metal fi lter is
vibrating.
1. Metal fi lter is loose.
1. Change the metal fi lter.
2. Spring clip is broken.
2. Change the spring clip.