Closing Power Adjustment–

Control Valve Adjustments

Closing Speed Controls (Figure 1A or 1B and 2.)

Using “Power Adjustment Chart” from Page 3, select the

correct number of turns for power adjustment shaft that

corresponds with the installation. With 1/8” hex-key provided,

rotate adjustment shaft full 360° clockwise turns to desired

setting. After closer has been installed and proper

adjustments made to the sweep and latch, it may be

necessary to readjust spring power for good closing action.

(See Figure 2.)

Valve “S” Controls Sweep Range.

Valve “L” Controls Latch Range.

Valve “D” Controls Delay Range (optional).

Unit Adjustment

LA

TC

H

LA

TC

H

Delayed Action

Closing Cycle

1B

Closing Speed Controls

Figure 1.

SWEEP

SW

EE

P

Attention : Adjust Closing Speed Time

to between 4 to 7 seconds from 90°.

Use of the door by handicapped,

elderly or small children may require

greater closing time.

CLOSED

CLOSED

Standard Closing Cycle

1A

DELAY R

ANG

E

10°

10°

70°

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Closing Speed Controls

Figure 2.

Slow

1/8”

Hex

Key

Fast

Latch

Valve

Sweep

Valve

Delay Valve

Closing Power Control

Figure 3.

Opening Cycle

Cover–

“Backcheck” valve controls the strength of cushioning in

Backcheck Range. NEVER close this valve completely – it

is not to provide a positive stop. (see Figure 4 and Figure 5).

Full cover: Slide cover insert into the un-used cutout

in cover. Install cover using screws provided.
Narrow cover: Install cover using screws provided. Install

pinion cap onto pinion shaft by hand or with a Phillips screw

driver - DO NOT OVER TIGHTEN.
Metal cover: Fasten cover to mounting clips with screws

provided.
Architectural Metal Cover: Remove cover insert where

pinion is located. Install standoffs in ends of closer. Install

cover using screws provided.
Architectural Plastic Cover: Slide cover insert into the un-

used cutout in cover. Install standoffs in ends of closer.

Snap cover over standoffs.

.

Slow

1/8”

Hex

Key

Fast

Slow

1/8”

Hex

Key

Fast

1902 Airport Road, Monroe, NC

Telephone:(800)-438-1951; Fax: (800)-338-0965

www.yalesecurity.com

Security Group

O

PE

NI

NG

Opening Door Control

Figure 4.

Opening Cycle

BACKCHE

CK

CAUTION:

DO NOT BACK VALVES OUT OF

CLOSER OR A LEAK WILL

RESULT.

Decrease

Increase

Backcheck Control

Figure 5.

Backcheck Valve*

1/8”

Hex

Key

Decrease

Increase

5/16” Socket

or Adjustable Wrench

Power Adjustment Shaft

NOTE: Maximum of 20 360° turns

of Power Adjustment Shaft

NEVER CLOSE VALVES

COMPLETELY - NOT

INTENDED TO PROVIDE

A POSITIVE STOP.

Cover Mounting

Figure 6.

An ASSA ABLOY Group Co.

Содержание PR3301

Страница 1: ...ions In those cases use this instruction sheet for installation sequence and closer adjustments only Narrow Frame Installation Closer mounts on opposite to hinge push side of door CLP3501 CloserPlus arm illustrated Full Cover shown 890 and 891 accessories required for this application supplied separately See Pages 3 and 4 Right Hand Door RH Left Hand Reverse LHR Left Hand Door LH Right Hand Revers...

Страница 2: ...ine Plastic Cover Cover Clips Cover Screw Cover Screws Optional 3501M Full Metal Cover Insert Cutouts Cover Insert Optional Architectural Plastic Cover Standoff Standoff Insert Cutouts Cover Insert Standard 3501 Full Plastic Cover Cover Screw Cover Screws Optional Architectural Metal Cover Standoffs CLP Arm Assembly Stop only Riveted Elbow Removable Stop PR Hold Open Arm Assembly Riveted Elbow Fri...

Страница 3: ...nstructions below see page 6 before installing cover using parallel mount S L L Left R Right Make closer adjustments CAUTION Do not back valves out of closer completely or a leak will result use spacer blocks 293S or 891 if required Reopen valves by turning counter clockwise With door closed align soffit plate with mounting holes in frame Fasten soffit plate to frame with flat head screws provided...

Страница 4: ... Ref 16 2 3 4 70 2 51 3 8 10 5 16 8 1 25 2 1 16 52 7 16 11 Use 9 16 14 in openings with blade stops C LHinge or Pivot 12 305 3 4 19 3 1 4 79 B A Narrow Frame Soffit Plate 890 Bracket 891 Block Soffit Plate 5 8 Ref 16 2 3 4 70 2 51 3 8 10 1 25 2 1 16 52 7 16 11 C L Hinge or Pivot 12 305 3 4 19 3 1 4 79 3 4 19 1 1 4 32 890 Bracket 2 to 2 3 4 51 to 70 B A Flush Partition Soffit Plate 2 1 2 64 1 1 2 3...

Страница 5: ...oor open to opening angle desired and tighten holder adjustment nut wrench supplied or use 1 Box or Open End wrench The Thumbturn Hold Open feature is controlled by the knob located on the arm of the unit Turning this knob clockwise will engage the Hold Open mechanism and increase the Hold Open force Turning this knob counterclockwise will reduce the Hold Open force and disengage the Hold Open mec...

Страница 6: ...ck valve controls the strength of cushioning in Backcheck Range NEVER close this valve completely it is not to provide a positive stop see Figure 4 and Figure 5 Full cover Slide cover insert into the un used cutout in cover Install cover using screws provided Narrow cover Install cover using screws provided Install pinion cap onto pinion shaft by hand or with a Phillips screw driver DO NOT OVER TI...

Отзывы: