Figure 36. Manual Hydraulic End Point Calibration
1
With no load on the forks, raise them, if they are not already raised.
2
Starting from the Calibration Menu, scroll to the Manual Hydraulic End Point Calibration screen and
press the
Enter Key
.
3
When prompted, move all hydraulic levers to both of their extreme locations; that is, move each lever
as far as it will go in both directions.
4
Press the
Enter Key
. The system records the extreme locations and returns to the Calibration Menu.
Display Menu
INTRODUCTION
The Display Menu is a main menu (top-level menu) that is visible at Supervisor and Service Technician
password access levels. To access this menu, cycle through the main level menu screens by pressing the
Scroll Back Key
(
!!
—
) or
Scroll Forward Key
(
—
▸
) until the Display Title Screen is displayed, as shown in
.
Figure 37. Display Title Screen
Содержание ERC030VA
Страница 8: ...Figure 3 Supervisor Flowchart Sheet 1 of 4 ...
Страница 9: ...Figure 3 Supervisor Flowchart Sheet 2 of 4 ...
Страница 10: ...Figure 3 Supervisor Flowchart Sheet 3 of 4 ...
Страница 11: ...Figure 3 Supervisor Flowchart Sheet 4 of 4 Table 1 Supervisor Menu Flowchart A B C D E F G H ...
Страница 21: ...Hydraulics Icon Alert Screens Cycle the Key Secure Battery Release Park Brake ...
Страница 22: ...Operator Out of Seat Release Pedal Release Hydraulic Input Traction Switch ...
Страница 23: ...Hydraulic Switch Temperature Too High Lift Limit Charge Battery ...
Страница 26: ...Display Title Screen Status Title Screen Truck Setup Title Screen ...
Страница 105: ...Figure 71 Steering Wheel Number of Turns Valid Entry ...