Page 11
Copyright ©2015 Yale Security Inc., an ASSA ABLOY Group Company. All rights reserved. Reproduction
in whole or in part without the express written permission of Yale Security Inc. is prohibited.
An ASSA ABLOY Group Brand.
Exit Devices
6116 Series
For technical support, contact Y ale
®
at
800.438.1951 x5033 or support@y alelocks.com
80-9460-6011-000 11/18
1. Check the following parts to be sure they are operating properly:
• Trim and Touchbar
• Strike Plate and Bolt Engagement
• Key
2. Test the alarm, as follows:
a. To actuate the alarm, turn the key clockwise. Wait 20 seconds to hear a confi rmation chirp.
1. Press the Touchbar to be sure the alarm sounds.
2. Turn the key counter-clockwise to shut off the alarm.
b. Actuate the alarm again by turning the key clockwise. Wait 20 seconds to hear a confi rmation chirp.
1. Slide the Alarm Assembly as if removing it. The alarm should sound.
2. Turn the key counter-clockwise to shut off the alarm.
3. Testing is complete if the alarm was activated successfully in numbers 2.a.1. and 2.b.1.
4. Refer to Section I if the alarm did not sound during testing.
H
Testing
If the Alarm will not sound, check the following:
• The Switch Lever may be out of position.
The end of the Switch Lever should be touching the Alarm Switch. Turn the Switch Lever Screw until the end contacts the
Alarm Switch (Section F).
• The Battery is not connecting.
Be sure the battery is placed securely.
Press to make contact (Section E).
• The Alarm is not armed.
To actuate the alarm, turn the key clockwise. Wait 20 seconds to hear a confi rmation chirp. The Battery needs to be
replaced.
If the Alarm chirps every 30 seconds:
• This is a low battery indicator and the battery needs to be replaced.
I
Troubleshooting
J
Maintenance
Periodically replace the 9-Volt battery to keep the Alarm Switch Activator working properly.