background image

FCC ID: K66VX-2500V

 Alignment

Vertex Standard Co., Ltd.

6/6

        

Actual DCS Deviation(Narrow):0.35[kHz]

- [6] LTR Deviation

This parameter is used to align the LTR deviation. 
Press [Enter] on "[6] LTR Deviation " to align LTR Deviation. 
Select the Channel 1 in alignment range.
Press the [Space] key on the keyboard to activate the transmitter, and injects a LTR
test tone.
Press the [UP]/[DWN] key, as need, to set the LTR Deviation  (Wide) to the following
specification.  
Press [Enter] to lock in the new data.
Select the Channel 2, and set the LTR deviation (Narrow), same as Channel 1.

        LTR Deviation(Wide)     :0.80[kHz](

±

0.1[kHz])

        LTR Deviation(Narrow) :0.60[kHz](

±

0.1[kHz])

The actual LTR deviation will increase around 20% based on the above alignment as
follows,

Actual LTR Deviation(Wide)    :1.00[kHz]

        

Actual LTR Deviation(Narrow):0.70[kHz]

[1]

 

Common RX

- [0] Tight NSQL

This parameter is used to align the noise level in squelch Tight.
It adjusts this alignment RX Tuning after ending. 
Select the MID frequency channel in alignment range.
Set the SG output level to -2.5dB

µ

V

, and obey the message.

- [1] Threshold NSQL

This parameter is used to align the noise level in squelch Threshold.
It adjusts this alignment RX Tuning after ending. 
Select the MID frequency channel in alignment range.
Set the SG output level to -8.5dB

µ

V

, and obey the message.

- [2] RX Tune

This parameter is used to align RX Tune.
Select the MID frequency channel in alignment range.
Set the SG output level to -8.0dB

µ

V

.

Pressing the [DWN] key, reduce the RX Tune Level and set the SINAD above 12dB.

 

Содержание VX-2500V

Страница 1: ...lacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Vertex Standard reserves the right to change circuits and alignment procedures in the interest of improved performance without notifying owners Under no circumstances should...

Страница 2: ...be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 and 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed time to come to room temperature before alignment Whenever possible alignments should be made with oscillator shields and circuit boards firmly affixed in place Also the test equipmen...

Страница 3: ...lignment mode normal operation is suspended Use the alignment tool program running on PC PLL VCV Connect the positive lead of the DC voltmeter to the test point TP1007 VCV on the RF Unit as indicated in the figure and the negative lead to chassis ground Set the transceiver to the high band edge frequency channel then adjust coil L1017 on the Unit for 4 25V on the voltmeter Key the transmitter and ...

Страница 4: ...ct the Channel 1 in alignment range Press the Space key on the keyboard to activate the transmitter Press the UP DWN key as need to set the power output to the following specification as indicated on the external wattmeter Tx Power High 25 W 0 5W When the 25Watt level is attained press Enter to lock in the new data 1 Tx Power Low This parameter is used to align TX Low power 5W Press Enter on 1 Tx ...

Страница 5: ... on 4 CTCSS Deviation to align CTCSS Deviation Select the Channel 1 in alignment range Press the Space on the keyboard to activate the transmitter and injects a CTCSS test tone Press the UP DWN key as need to set the CTCSS Deviation Wide to the following specification Press Enter to lock in the new data Select the Channel 2 and set the CTCSS Deviation Narrow same as Channel 1 CTCSS Deviation Wide ...

Страница 6: ...on will increase around 20 based on the above alignment as follows Actual LTR Deviation Wide 1 00 kHz Actual LTR Deviation Narrow 0 70 kHz 1 Common RX 0 Tight NSQL This parameter is used to align the noise level in squelch Tight It adjusts this alignment RX Tuning after ending Select the MID frequency channel in alignment range Set the SG output level to 2 5dBµV and obey the message 1 Threshold NS...

Отзывы: