Vertex Standard Co., Ltd.

key until the Preset Channel number to be deleted is displayed, then release the

PRESET

 key.

4.14.2 Operation

Pressing the 

PRESET

 key toggles between Preset Channel A, b, C, d, E, and regular

channel. Preset Channel A is represented by “A” to the left of the channel number on the
LCD, and channel B is represented by “b” ……. Do not confuse this “A” with the one that
sometimes is displayed to the right of the channel number (described in the section 3.2 of
this Owner’s Manual).

4.15 SIMPLEX/DUPLEX CHANNEL USE

All channels are factory-programmed in accordance with FCC (USA), Industry Canada and
International regulations. Mode of operation cannot be altered from simplex to duplex or
vice-versa. Simplex or duplex mode is automatically activated, depending on the channel
and whether USA, International or Canadian operating mode is selected. Refer to the
channel charts in the OWNER’S MANUAL SUPPLEMENT.

4.16 SET MODE

The 

HX370S

’s Set Mode system allows a number of transceiver operating parameters to be

custom-configured for your operating requirements.

The Set Mode is easy to activated and set, using the following procedure:
1.  Turn the radio off.
2.  Hold down the 

SQ

 switch and then turn on the transceiver.

3. The 

SET

” will appear on the display, indicate that activate the Set Mode.

4. Press 

the 

SQ

 switch to select the Menu item to be adjusted.

5.  Press the [UP] or [DOWN] key select the status or value of the Menu item. Then press

SQ

 switch to save the new setting.

6.  After completing your adjustment, press the 

PTT

 switch to save the new setting and exit

to normal operation.

4.16.1 bEP (Key Beep)

Function: Enable/disable Keypad beeper.
Available Values: ON/OFF
Default: ON

4.16.2 CHF (Channel Frequency Display)

Function: Select the frequency of each channel.
Available Values: ON/OFF
Default: OFF

4.16.3 CHn (Channel Name)

Function: Input channel name of each channel.
Available Values: Alphanumeric
Default:

4.16.4 dUL (Dual Watch)

Function: Select the Dual Watch channel.
Available Values: SPL/NOR
Default: SPL

4.16.5 LP (Lamp Mode)

Function: Select the LCD/Keypad Lamp mode.
Available Values: KEY/CNT (Continuous)/OFF

Содержание HX370S

Страница 1: ...restricted to occupational use work related operations only where the radio operator must have the knowledge to control its RF exposure conditions When transmitting hold the radio in a vertical posit...

Страница 2: ...ENSE INFORMATION This radio operates on communications frequencies which are subject to FCC Federal Communications Commission Rules and Regulations FCC Rules require that all operators using Marine Pr...

Страница 3: ...nd 5 watts High Emission 16K0G3E Marine Band 16K0F3E 11K0F3E LMR Band Frequency Range 156 025 157 425 MHz Marine Band 137 174 MHz LMR Band FCC Type Number Industry Canada Type Approval Additional FCC...

Страница 4: ...down the channels decrease continuously 6 16 9 KEY Immediately recalls channel 16 from any channel location Holding down this key recalls channel 9 7 SCAN KEY Starts scanning programmed channels Pres...

Страница 5: ...ional mode H M L Indicator H is high power M is middle power and L is low power Blank is a reception only channel PRI Indicator Priority Scan is activated SCN Indicator Scan is activated TX Indicator...

Страница 6: ...this point weak signals may not be received No noise or no signal is heard until a signal is received that exceeds the squelch threshold 5 To change channel press the UP or DOWN key Sometimes a slight...

Страница 7: ...e LCD 3 Repeat steps 1 and 2 for all the channels to be scanned 4 To delete a channel from the transceiver s scan memory press the MEM key again while the memorized channel is displayed MEM disappears...

Страница 8: ...9 Channel 9 is used as a hailing channel for initial non emergency contact with other vessels Hold down the 16 9 key for 1 second to select channel 9 4 12 OPERATING ON CHANNEL 13 Channel 13 is used at...

Страница 9: ...MODE The HX370S s Set Mode system allows a number of transceiver operating parameters to be custom configured for your operating requirements The Set Mode is easy to activated and set using the follo...

Страница 10: ...the Source transceiver cS will appear on the Source radio and the data is transferred 6 If there is a problem during the cloning process cE will displayed Check your cable connections and battery vol...

Страница 11: ...dride Ni MH FNB 83 or Nickel cadmium Ni Cd FNB V57IS batteries This type of battery stores a charge powerful enough to be dangerous if misused or abused especially when removed from the transceiver Pl...

Страница 12: ...r s memory The SCAN key does not start the scan Squelch is not adjusted Adjust the squelch to threshold or to the point where noise just disappears Further adjustment of the squelch control may elimin...

Страница 13: ...range 20 to 60 C Marine 30 to 60 C LMR Case size W x H x D 58 x 120 x 30 5 mm Weight Approx 340 g Receiver Circuit type Double conversion superheterodyne Ifs 1st 21 7 MHz 2nd 450 kHz 12dB SINAD Sensit...

Страница 14: ...device complies with Part 15 of the FCC Rules Operation is subject to the condition that this device does not cause harmful interference Part 15 21 Changes or modifications to this device not express...

Отзывы: