16
FTM-350AR/E Technical Supplement
Alignment
26.Press the
PTT
switch to activate the transmitter,
adjust the left
DIAL
knob so that the Deviation
Meter reading is 0.60 kHz ~ 0.80 kHz.
Center Meter Calibration
1. Set the RF signal generator to 440.050 MHz. Set
the generator for ±3.5 kHz (Narrow FM) or ±22.5
kHz (Wide FM) deviation of a 1 kHz modulation
tone, and set the RF output level from the signal
generator to +10 dB
μ
V.
2. Set the transceiver frequency to 440.050 MHz.
3. Press the [
SET
] key to enter the SET mode.
4. Rotate the left
DIAL
knob to select Menu Item "TX/
RX".
5. Press the left
DIAL
knob, then rotate the left
DIAL
knob to select "B08 WIDE/NARROW AUTO".
6. Press the left
DIAL
knob, then rotate the left
DIAL
knob to select "AUTO (FM)".
7. Press the [
ESC
] key repeatedly, to save the new
setting and exit the Menu mode.
8. Press the [
ADJ
] key to set the alignment Menu
Item “
CTRA UP
CTRA UP
CTRA UP
CTRA UP
CTRA UP
”.
9. Press the [
FWD
] key to save the new setting.
10.To change the mode to "NAR FM", just repeat
steps 3 through 7 above, rotating the left
DIAL
knob to select "NAR FM" in step 6 above.
11.Press the [
FWD
] key to save the new setting.
12.To change the mode to "WIDE FM", just repeat
steps 3 through 7 above, rotating the left
DIAL
knob to select "WIDE FM" in step 6 above.
13.Press the [
ADJ
] key to save the new setting.
14.Press and hold in the [
ADJ
] key for one second,
to set the alignment Menu Item “
CTRB UP
CTRB UP
CTRB UP
CTRB UP
CTRB UP
”.
15.Just repeat all steps above, in "SUB BAND".
VOX Alignment
1. Press the [
ADJ
] key to set the alignment Menu
Item “
VOX UP
VOX UP
VOX UP
VOX UP
VOX UP
”.
2. Press the [
FWD
] key to save the new setting.
To close the alignment mode, just turn the power off by
pressing and holding the
POWER
switch for two sec-
onds. The next time the transceiver is turned on, normal
operation will resume.
Содержание FTM-350AE
Страница 4: ...7 Block Diagram FTM 350AR E Technical Supplement...
Страница 13: ...17 MAIN Unit Lot 1 4 FTM 350AR E Technical Supplement Circuit Diagram...
Страница 16: ...21 MAIN Unit Lot 5 FTM 350AR E Technical Supplement Circuit Diagram...
Страница 17: ...25 MAIN Unit Lot 27 FTM 350AR E Technical Supplement Circuit Diagram...
Страница 52: ...63 PANEL Unit Lot 12 FTM 350AR E Technical Supplement Circuit Diagram...
Страница 61: ...73 PANEL R Unit Lot 6 11 FTM 350AR E Technical Supplement Circuit Diagram...
Страница 63: ...75 PANEL R Unit Lot 12 FTM 350AR E Technical Supplement Circuit Diagram...