background image

9

Advanced Operation

FTM-3100R Advance Manual

Activating the Enhanced Paging & Code Squelch System

1.  Press and hold in the [

MHz

(

SETUP

)] key for 

one second to enter the Set mode.

2. Rotate the 

DIAL

 knob to select “

SQL TYPE 

34

”.

VOL

DIAL

D W

M W

SETUP

REV

SQL

TXPO

V / M

M H z

3. Press  the  [

MHz

(

SETUP

)] key, and then 

rotate the 

DIAL

 knob to select “PAGER”.

4. Press and hold in the [

MHz

(

SETUP

)] key for one second to save the new setting and 

exit to normal operation.

5. To disable the Enhanced Paging & Code Squelch, just repeat the above procedure, 

rotating the 

DIAL

 knob to select “OFF” in step 3 above.

When the Enhanced Paging & Code Squelch 
feature is activated, the “P” notation will appear 
on the right of the frequency display.

Содержание FTM-3100R

Страница 1: ...FTM 3100R Advance Manual VOL DIAL SQL D W M W SETUP REV TXPO V M MH z VHF FM TRANSCEIVER...

Страница 2: ...e 11 Transmitting the registered DTMF code 12 Setting DTMF Autodialer sending Speed 12 Setting DTMF Autodialer TX delay time 13 Memory Operation 14 Split Memory 14 Moving Memory Data to the VFO 14 Mem...

Страница 3: ...one second to save the new setting and exit to normal operation VOL DIAL D W M W SETUP REV SQL TXPO V M MHz RF Squelch A special RF Squelch feature is provided on this radio which allows setting the...

Страница 4: ...to allow un muted reception HOME Recall the home channel WX CH Switches operation to the Weather channels bank CD SRCH Engages the Tone or DCS Search Scanning feature SCAN Engages the Scan operation...

Страница 5: ...then rotate the DIAL knob to select ON Default OFF VOL DIAL D W M W SETUP REV SQL TXPO V M MHz 4 Press the MHz SETUP key momentarily then rotate the DIAL knob to select SQL TYPE 34 5 Press the MHz SE...

Страница 6: ...correct tone scanning will halt on that tone and audio will be allowed to pass 4 Press the assigned Programmable key of the Microphone to lock in that tone and exit to normal operation Note You may l...

Страница 7: ...he correct code scanning will halt on that code and audio will be allowed to pass 4 Press the assigned Programmable key of the Microphone to lock in that tone and exit to normal operation Note You may...

Страница 8: ...transmitted automatically On the paged radio the squelch will close automatically after the incoming page ends Storing CTCSS Tone Pairs for EPCS Operation 1 Press and hold in the MHz SETUP key for one...

Страница 9: ...TXPO V M MHz 3 Press the MHz SETUP key and then rotate the DIAL knob to select PAGER 4 Press and hold in the MHz SETUP key for one second to save the new setting and exit to normal operation 5 To dis...

Страница 10: ...in the following table 1209 Hz 1336 Hz 1477 Hz 1633 Hz 697 Hz 1 2 3 A 770 Hz 4 5 6 B 852 Hz 7 8 9 C 941 Hz 0 D Transmitting a DTMF code manually You can generate DTMF tones during transmission manual...

Страница 11: ...can also use the keypad on the microphone to input the DTMF code 5 When you have selected the correct digit press the V M MW key momentarily Now rotate the DIAL knob to select the second of 16 availa...

Страница 12: ...s the microphone numeric key 0 through 9 corresponding to the DTMF memory string you wish to send Once the string begins you may release the PTT switch as the transmitter will be held on the air until...

Страница 13: ...in the MHz SETUP key for one second to enter the Set mode 2 Rotate the DIAL knob to select DT DELAY 11 3 Press the MHz SETUP key momentarily and then rotate the DIAL knob to select the desired delay t...

Страница 14: ...ved to the VFO 1 Select the memory channel containing the frequency data to be moved to the VFO 2 Press and hold in the V M MW key for one second and then press the MHz SETUP key The VFO WRT will appe...

Страница 15: ...key to back space the cursor then re enter the correct letter number or symbol 7 Repeat steps 5 through 6 to program the re maining letters numbers or symbols of the desired label A total of 8 charac...

Страница 16: ...al disappears and then restart scan ning 2 seconds after the signal disappears BUSY 3 Stop scanning and receive that frequency HOLD 1 Press and hold in the MHz SETUP key for one second to enter the Se...

Страница 17: ...one second then rotate the DIAL knob to select SCAN SKP 32 4 Press the MHz SETUP key then rotate the DIAL knob to select SKIP The current Memory Channel will now be ignored during scanning VOL DIAL D...

Страница 18: ...l number appear on the right side of the display 2 Rotate the DIAL knob to select the Memory Channel that you wish to add to the prefer ential Scan List VOL DIAL D W M W SETUP REV V M MHz SQL TXPO 3 P...

Страница 19: ...L DIAL D W M W SETUP REV V M MHz SQL TXPO Note While operating in the Memory Storage mode the keypad of the MH 48A6JA Microphone may be used to enter the memory channel number directly To do this ente...

Страница 20: ...scanning stops press the key on the MH 48A6JA Microphone Band Edge Beeper The FTM 3100R will automatically beep when the receive band edge is encountered during scanning either in standard VFO scanni...

Страница 21: ...set the FTM 3100R for operation on an other memory channel Home channel or on a VFO frequency 6 Press and hold in the REV DW key for one second The display will remain on the VFO the selected memory c...

Страница 22: ...y activated in this step 4 On the Destination radio press the MHz SETUP key WAIT will appear on the display 5 On the Source radio press the REV DW key TX will appear on the Source radio and the data f...

Страница 23: ...e Values Default 1 APO Enables Disables the Automatic Power Off feature 0 5H to 12H 0 5H step OFF OFF 2 BCLO Enables Disables the Busy Channel Lock Out feature ON OFF OFF 3 BEP KEY Enables Disables th...

Страница 24: ...2 Programming the function assigned to Microphone P2 key HOME 25 PRG P3 Programming the function assigned to Microphone P3 key DIG ANA 26 PRG P4 Programming the function assigned to Microphone P4 key...

Страница 25: ...FAST 41 VER DISP Displays the transceiver software version CPU x xx DSP x xx 42 WX ALERT Enables Disables the Weather Alert fea ture ON OFF OFF 43 WX VOL Selects the audio output level of the Weather...

Страница 26: ...is pressed or when the scanner stops KEY The beeper sounds when any key is pressed OFF Beeper is disabled 4 BEP EDGE Function Enables Disable the Band edge beeper while scanning Available Values ON O...

Страница 27: ...nication direction Available Values NORMAL INVERT BOTH Default NORMAL NORMAL Homeomorphic INVERT Inverted Phase BOTH Both Phase 10 DT AUTO Function Enables Disables the DTMF Autodialer feature Availab...

Страница 28: ...ening Message that appears when the radio is powered ON Available Values DC MESSAGE OFF Default MESSAGE DC DC supply voltage MESSAGE Set by user See below OFF No Opening Message Here s how to program...

Страница 29: ...vailable Values SQL OFF HOME WX CH CD SRCH SCAN T CALL TX POWER or one of the all Set mode items except Set mode items 23 through 26 initial setting is Set mode item 15 LCD DMMR Default HOME 25 PRG P3...

Страница 30: ...and will not restart 2 0 SEC 10 0 SEC The scanner will hold for the selected resume time then resume scanning whether or not the other station is still transmitting 32 SCAN SKP Function Selects the Me...

Страница 31: ...e current temperature inside the transceiver 37 TONE FRQ Function Setting of the CTCSS Tone Frequency Available Values 50 standard CTCSS tones Default 100 0 Hz CTCSS TONE FREQUENCY Hz 67 0 69 3 71 9 7...

Страница 32: ...alues CPU 42 WX ALERT Function Enables Disables the Weather Alert feature Available Values ON OFF Default OFF ON The weather alert will be received OFF The weather alert will not be received 43 WX VOL...

Страница 33: ...mission of YAESU MUSEN CO LTD Copyright 2016 1605 B0 YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 9063...

Отзывы: