background image

19

CAT

 (Computer Aided Transceiver) 

Operation

PS

POWER SWITCH

Set

1

2

3

4

5

6

7

8

9

10

P1  0: POWER “OFF”

 

1: POWER “ON”

This command requires dummy data be initially sent. Then after one second and before 

two seconds the command is sent. (For example, Send “PS1;” command, wait 1 second, 

and then Send “PS1;” command again within 2 seconds.)

When using an RS-232C cable, the PS command (POWER SWITCH) is not 

available , so the transceiver cannot be turned ON with the CAT command.

P

S

P1

;

Read

1

2

3

4

5

6

7

8

9

10

P

S

;

Answer

1

2

3

4

5

6

7

8

9

10

P

S

P1

;

QI

QMB STORE

Set

1

2

3

4

5

6

7

8

9

10

Q

I

;

Read

1

2

3

4

5

6

7

8

9

10

Answer

1

2

3

4

5

6

7

8

9

10

QR

QMB RECALL

Set

1

2

3

4

5

6

7

8

9

10

Q R

;

Read

1

2

3

4

5

6

7

8

9

10

Answer

1

2

3

4

5

6

7

8

9

10

QS

QUICK SPLIT

Set

1

2

3

4

5

6

7

8

9

10

Q S

;

Read

1

2

3

4

5

6

7

8

9

10

Answer

1

2

3

4

5

6

7

8

9

10

RA

RF ATTENUATOR

Set

1

2

3

4

5

6

7

8

9

10

P1  0: Fixed
P2  0: OFF

 

1: 6dB

 

2: 12dB

 

3: 18dB

R A

P1 P2

;

Read

1

2

3

4

5

6

7

8

9

10

R A

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

R A

P1 P2

;

RC

CLAR CLEAR

Set

1

2

3

4

5

6

7

8

9

10

R C

;

Read

1

2

3

4

5

6

7

8

9

10

Answer

1

2

3

4

5

6

7

8

9

10

RD

CLAR DOWN

Set

1

2

3

4

5

6

7

8

9

10

P1  0000 - 9990 (Hz)

R D

P1 P1 P1 P1

;

Read

1

2

3

4

5

6

7

8

9

10

Answer

1

2

3

4

5

6

7

8

9

10

RF

ROOFING FILTER

Set

1

2

3

4

5

6

7

8

9

10

P1  0: Fixed

P2  1: 12 kHz 

P3:  6: 12 kHz

 

2: 3 kHz 

 

7: 3 kHz

 

3: - 

 

8: -

 

4: 500 Hz 

 

9: 500 Hz

 

5: 300 Hz (option) 

 

A: 300 Hz

R

F

P1 P2

;

Read

1

2

3

4

5

6

7

8

9

10

R

F

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

R

F

P1 P3

;

Содержание FTDX10

Страница 1: ...YAESU MUSEN CO LTD CAT Operation Reference Manual...

Страница 2: ...long with the short programming examples is intended to help you start writing programs on your own As you become more familiar with CAT operation you can customize programs for your operating needs a...

Страница 3: ...rt configuration select the COM port numbers that were confirmed using the procedure above If a or X is displayed for the port on the Device Manager uninstall and reinstall the virtual COM driver If a...

Страница 4: ...on your computer Purchase a standard serial cable not the so called null modem type ensuring it has the correct gender and number of pins some serial COM port connectors use a 9 pin rather than 25 pin...

Страница 5: ...may use either lower or upper case characters The commands available for this transceiver are listed in the PC Control Command Tables on the following pages Parameters Parameters are used to specify...

Страница 6: ...B O X X X MC MEMORY CHANNEL O O O X MD MODE O O O O MG MIC GAIN O O O O ML MONITOR LEVEL O O O O MR MEMORY READ X O O X MS METER SW O O O O MT MEMORY CHANNEL WRITE TAG O O O X MW MEMORY WRITE O X X X...

Страница 7: ...FF 1 Auto Information ON NOTE The AI command is available only when PC is connected with USB cable This parameter is set to 0 OFF automatically when the transceiver is turned OFF A I P1 Read 1 2 3 4 5...

Страница 8: ...8 9 10 BP MANUAL NOTCH Set 1 2 3 4 5 6 7 8 9 10 P1 0 Fixed P3 P2 0 P2 0 Manual NOTCH ON OFF 000 OFF 1 Manual NOTCH Frequency 001 ON P2 1 001 320 NOTCH Frequency x 10 Hz B P P1 P2 P3 P3 P3 Read 1 2 3...

Страница 9: ...6 233 6 Hz 002 71 9 Hz 011 97 4 Hz 020 131 8 Hz 029 167 9 Hz 038 196 6 Hz 047 241 8 Hz 003 74 4 Hz 012 100 0 Hz 021 136 5 Hz 030 171 3 Hz 039 199 5 Hz 048 250 3 Hz 004 77 0 Hz 013 103 5 Hz 022 141 3 H...

Страница 10: ...2 01 99 Frequency Steps Frequency only P2 01 Fixed Except Frequency E D P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 EM ENCODE MEMORY Set 1 2 3 4 5 6 7 54 55 P1 0 RTTY 1 DATA P2 0 3...

Страница 11: ...17 RPTT SELECT 0 DAKY 1 RTS 2 DTR 1 03 MODE FM 01 AF TREBLE GAIN 10 00 10 3 02 AF MIDDLE TONE GAIN 10 00 10 3 03 AF BASS GAIN 10 00 10 3 04 AGC FAST DELAY 20 4000 msec P4 0020 4000 20 msec step 4 05...

Страница 12: ...1 11 CW OUT LEVEL 0 100 P4 000 100 3 12 CW AUTO MODE 0 OFF 1 50 MHz 2 ON 1 13 CW BK IN TYPE 0 SEMI 1 FULL 1 14 CW WAVE SHAPE 0 1 msec 1 2 msec 2 4 msec 3 6 msec 1 15 CW FREQ DISPLAY 0 DIRECT FREQ 1 PI...

Страница 13: ...4 1800 05 1900 06 2000 18 3200 Hz 2 18 P PRMTRC EQ3 LEVEL 20 0 10 P4 20 00 or 00 10 3 19 P PRMTRC EQ3 BWTH 01 10 2 04 TX GENERAL 01 HF MAX POWER 5 100 P4 005 100 3 02 50M MAX POWER 5 100 P4 005 100 3...

Страница 14: ...2 3 4 5 6 7 8 9 10 P1 0 Fine Tuning OFF 1 Fine Tuning ON F N P1 Read 1 2 3 4 5 6 7 8 9 10 F N Answer 1 2 3 4 5 6 7 8 9 10 F N P1 FT FUNCTION TX Set 1 2 3 4 5 6 7 8 9 10 P1 0 1 2 MAIN Band Transmitter...

Страница 15: ...P2 P3 P3 P3 P3 P3 P4 21 22 23 24 25 26 27 28 29 30 P5 P6 P7 P8 P9 P9 P10 IS IF SHIFT Set 1 2 3 4 5 6 7 8 9 10 P1 0 Fixed P2 0 Fixed P3 P4 0 1200 Hz 20 Hz steps I S P1 P2 P3 P4 P4 P4 P4 Read 1 2 3 4 5...

Страница 16: ...ing Start Stop 5 DVS CH 5 Recording Start Stop L M P1 P2 Read 1 2 3 4 5 6 7 8 9 10 L M P1 Answer 1 2 3 4 5 6 7 8 9 10 L M P1 P2 MA MEMORY CHANNEL TO VFO A Set 1 2 3 4 5 6 7 8 9 10 M A Read 1 2 3 4 5 6...

Страница 17: ...ID 5 SWR M S P1 P2 Read 1 2 3 4 5 6 7 8 9 10 M S Answer 1 2 3 4 5 6 7 8 9 10 M S P1 P2 MT MEMORY CHANNEL WRITE TAG Set 1 2 3 4 5 6 7 8 9 10 P0 1 001 099 Memory Channel P1L P9U PMS 5xx 5MHz BAND EMG EM...

Страница 18: ...Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 MX MOX SET Set 1 2 3 4 5 6 7 8 9 10 P1 0 MOX OFF 1 MOX ON M X P1 Read 1 2 3 4 5 6 7 8 9 10 M X Answer 1 2 3 4 5 6 7 8 9 10 M X P1 NA NARROW Set 1...

Страница 19: ...Simplex 1 Plus Shift 2 Minus Shift This command can be activated only with an FM mode O S P1 P2 Read 1 2 3 4 5 6 7 8 9 10 O S P1 Answer 1 2 3 4 5 6 7 8 9 10 O S P1 P2 PA PRE AMP IPO Set 1 2 3 4 5 6 7...

Страница 20: ...7 8 9 10 QR QMB RECALL Set 1 2 3 4 5 6 7 8 9 10 Q R Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 QS QUICK SPLIT Set 1 2 3 4 5 6 7 8 9 10 Q S Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8...

Страница 21: ...8 9 10 P1 0 P2 Meter 0 255 P3 000 Fixed P1 1 S 2 3 COMP 4 ALC 5 PO 6 SWR 7 IDD 8 VDD 9 P2 0 255 P3 000 Fixed Read 1 2 3 4 5 6 7 8 9 10 R M P1 Answer 1 2 3 4 5 6 7 8 9 10 R M P1 P2 P2 P2 P3 P3 P3 RS R...

Страница 22: ...dth P3 SSB CW RTTY PSK 00 Default Default Default Default Default 01 300 Hz 50 Hz 50 Hz 50 Hz 02 400 Hz 100 Hz 100 Hz 100 Hz 03 600 Hz 150 Hz 150 Hz 150 Hz 04 850 Hz 200 Hz 200 Hz 200 Hz 05 1100 Hz 25...

Страница 23: ...3 0 AF FFT ATT 0dB 1 AF FFT ATT 10dB 2 AF FFT ATT 20dB P4 0 OSC Level ATT 0dB 1 OSC Level ATT 10dB 2 OSC Level ATT 20dB P5 0 OSC Time 1msec 1 OSC Time 3msec 2 OSC Time 10msec 3 OSC Time 30msec 4 OSC T...

Страница 24: ...et 1 2 3 4 5 6 7 8 9 10 P1 000 100 V G P1 P1 P1 Read 1 2 3 4 5 6 7 8 9 10 V G Answer 1 2 3 4 5 6 7 8 9 10 V G P1 P1 P1 VM MAIN BAND TO MEMORY CHANNEL Set 1 2 3 4 5 6 7 8 9 10 V M Read 1 2 3 4 5 6 7 8...

Страница 25: ...roduced without the permission of YAESU MUSEN CO LTD YAESU MUSEN CO LTD Tennozu Parkside Building 2 5 8 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan YAESU USA 6125 Phyllis Drive Cypress CA 9063...