background image

18

 Scope Display Setting

In addition to the conventional two-dimensional waterfall spectrum display, Yaesu has added the 3-Dimen-

sion Spectrum Stream (3DSS) color display. The constantly changing band conditions and signals are 

depicted in real time and color. The frequency span is shown on the horizontal X axis, the vertical Y axis 

depicts the signals and their strengths, and the time is represented on the receding Z axis. The FT-710 

operator can intuitively grasp the band and signal conditions at any instant.

• CENTER/CURSOR/FIX

Switches the Spectrum Scope operation each time the key is touched.

• 

When the display area is touched, the receive frequency is moved to that point.

• 

In CENTER mode, the frequency touched becomes the center.

• 

In CURSOR and FIX mode, the marker and the receive frequency move to the touched position.

• CENTER

The receive frequency is always shown at the center 

of the screen and spectrum display. The band spec-

trum is shown within the range set by “SPAN”. The 

CENTER mode is convenient for monitoring the sig-

nal activity around the operating frequency.

 Marker*

 Current display mode (CENTER)

 Sweep Speed

 Scope Screen frequency span (display range).

*At factory shipment, marker display is ON.

• CURSOR

Monitors the spectrum within the range set with 

“SPAN”. When the frequency (marker) exceeds 

the upper limit or the lower limit of the range, the 

screen is automatically scrolled and the status be-

yond the setting range can be observed.

 The lower limit frequency of the display area.

 Marker* (Receive Frequency)

 Marker* (Transmit Frequency)

 Current display mode (CURSOR)

 Sweep Speed

 Scope Screen frequency span (display range).

 The upper limit frequency of the display area.

*At factory shipment, marker display is ON.

Содержание FT-710

Страница 1: ...Operation Manual FT 710...

Страница 2: ......

Страница 3: ...be performed either by touching the Function Screen or by turning and pressing the FUNC knob are abbreviated to Select DISPLAY SETTING DISPLAY LED DIMMER as described in the following Example How to...

Страница 4: ...the number of 28 QMB channels 28 RX Clarifier 30 TX Clarifier 30 Adjusting the Noise Blanker Level 31 Adjusting the Noise Attenuation 31 Reduces longer duration pulse noise 31 Voice Communications SSB...

Страница 5: ...d 48 Installing the SD card 48 Removing the SD card 48 Formatting a SD card 48 Saving Memory data and Setting Menu data 49 Reading Memory and Set Menu data 50 Display the SD Card Information 50 Option...

Страница 6: ...s in consid eration of people who are fitted with medical devices such as heart pacemakers Electromagnetic waves from the device may af fect the medical device resulting in accidents caused by malfunc...

Страница 7: ...loration Do not place this device in a location where there is a lot of dust and humidity Doing so may result in fire and equipment failure Stay as far away from the antenna as possible during transmi...

Страница 8: ...o the supplied microphone SSM 75E Reference Microphone M 1 Dual Element Microphone M 100 Desktop Microphone M 90D Microphone Stand Kit M 90MS Desktop Microphone M 70 Lightweight Stereo Headphone YH 77...

Страница 9: ...the station equipment to the buried ground rod or alternative earth ground system Power Cable Connections Carefully follow the illustrations regarding the proper connection of the DC power cable Use...

Страница 10: ...ne Key Keyer and FH 2 Connections DOWN UP 5V MIC GND MIC PTT GND FAST Remote Control Keypad FH 2 option as viewed from front panel 3 5mm Key up voltage is approximately 5 0 V DC and key down current i...

Страница 11: ...s when your hands are wet DC IN ANT LINEAR ALC 2 BAND DATA 2 GND GND CONTROL DC 48V IN ANT 1 ANT 2 ANT 3 INPUT 2 Coaxial Cable 50 ohm Connect to INPUT 2 of the VL 1000 HF 50MHz Antenna CT 118 Connecti...

Страница 12: ...key down current is 3 mA KEY NC GND When connecting a single straight key 13V OUT TX GND GND TUNER SENSE RESET OUT TX INH RX D TX D DOT DASH COMMON When connecting an electronic keyer paddle RTTY DATA...

Страница 13: ...e MUTE key the receiver audio from the speaker will be muted Microphone Speak into the microphone in a normal tone of voice with the microphone 5 cm away from the mouth P1 key This key toggles the ON...

Страница 14: ...larifier function is oper ating the offset difference between the receive frequency and the transmit frequen cy is displayed The functions that operate when the FUNC knob is turned are displayed Displ...

Страница 15: ...perating mode When touched the operation mode selection screen is displayed Touch the desired operation mode to select it Touch PRESET to display the settings that ap ply to the FT8 operation Operatio...

Страница 16: ...he transmit and receive frequencies of VFO B When the clarifier function is active the offset fre quency is displayed When the clarifier function is active The clarifier is used to adjust the transcei...

Страница 17: ...AY ANTI VOX RF POWER MONI LEVEL KEYER BK IN CW SPEED CW PITCH BK DELAY Adjust the reference level to make it easier to distinguish the scope display target signal from the noise Adjust the Peak Signal...

Страница 18: ...ea of the filter func tion display to clear the spectrum view To display it press and hold again Information displayed on the scope screen Scope screen information CENTER The receive frequency is alwa...

Страница 19: ...l can be attenu ated and S N greatly improved DNF Digital NOTCH Filter The Digital NOTCH Filter DNF is an effective beat canceling filter that can null out a number of interfering beat notes inside th...

Страница 20: ...e the marker and the receive frequency move to the touched position CENTER The receive frequency is always shown at the center of the screen and spectrum display The band spec trum is shown within the...

Отзывы: