Yaesu FT-65R Скачать руководство пользователя страница 17

FT-65R/FT-65E Advance Manual

16

Memory Only Mode

Once memory channel programming has been completed, the transceiver may be placed 
in a “Memory Only” mode, whereby VFO operation is impossible. 

1.  Turn the transceiver 

OFF

.

2.  Press and hold the 

MONI/T.CALL

 key and the 

PTT

 switch simultaneously, while turn-

ing the transceiver ON.
When the LCD backlight is on, release the 

MONI/T.CALL

 key and the 

PTT

 switch.

3.  Press the [▲] or [▼] key to select “

F5:MEM-ONLY

”.

4.  Press the 

F

 key momentarily to complete the procedure.

To return to normal operation, repeat the above power-on procedure.

Содержание FT-65R

Страница 1: ...Clicking tapping the at the bottom right of the current browsing page will return to the contents page at any time 144 430 MHz DUAL BAND TRANSCEIVER FT 65R FT 65E Advance Manual...

Страница 2: ...ed Paging Code Squelch 11 Storing the CTCSS Tone Pairs for EPCS Operation 11 Activating the Enhanced Paging Code Squelch System 12 Paging Answer Back 13 Memory Bank Operation 14 Assigning Memories to...

Страница 3: ...CW Identifier Setup 26 DTMF Operation 27 Manual DTMF Tone Generation 27 DTMF Autodialer 27 Sending the DTMF code by Autodialer 28 Miscellaneous Settings 29 Password 29 Setting a Password and Turning...

Страница 4: ...to important in formation Symbols Description This icon indicates cautions and alerts the user should be aware of This icon indicates helpful notes tips and information This icon indicates other pages...

Страница 5: ...Press and hold the F key to enter the Set Mode 2 Press the or key to select Set Mode Item 26 RF SQL 3 Press the F key to enable adjustment of this item 4 Press the or key to select the desired signal...

Страница 6: ...easure the current battery voltage 1 Press and hold the F key to enter the Set Mode 2 Press the or key to select Set Mode Item 10 DC VOLT 3 Press the F key to display the current DC Voltage 4 Press th...

Страница 7: ...OX system enabled you do not need to press the PTT switch in order to transmit 1 Press and hold the F key to enter the Set Mode 2 Press the or key to select Set Mode Item 35 VOX 3 Press the F key to e...

Страница 8: ...Dual Display Mode 5 Press and hold the F key to enter the Set Mode 6 Press the or key to select Set Mode Item 34 VFO SPL 7 Press the F key to enable adjustment of this item 8 Press the or key to selec...

Страница 9: ...appears on the LCD display T TONE Enables transmit only tone squelch function the icon appears on the LCD display TSQL Enables the tone squelch receive function the icon appears on the LCD display Mut...

Страница 10: ...eiving 5 Press the or key until the needed Tone Frequency is displayed Obtain the correct tone from the repeater owner operator if you don t know it CTCSS TONE FREQUENCY Hz 67 0 69 3 71 9 74 4 77 0 79...

Страница 11: ...311 315 325 331 332 343 346 351 356 364 365 371 411 412 413 423 431 432 445 446 452 454 455 462 464 465 466 503 506 516 523 526 532 546 565 606 612 624 627 631 632 654 662 664 703 712 723 731 732 734...

Страница 12: ...eiver the Enhanced Paging and Code Squelch system will be disabled after the PTT switch is released after the paging transmission The Enhanced Paging and Code Squelch system may be re activated again...

Страница 13: ...ing the Enhanced Paging Code Squelch System 1 To activate the EPCS function see page 8 Se lecting the Squelch Type The v icon will appear on the LCD display v While the EPCS function is activated the...

Страница 14: ...m 21 PAGER 3 Press the F key to enable adjustment of this item 4 Press the or key to select ACK then press the F key 5 Press the or key to select ON then press the F key 6 Press the PTT switch to save...

Страница 15: ...Band Channels 1 Recall the memory channel to be assigned to a Memory Bank 2 Press and hold the BAND key then press the or key to select the Mem ory Bank number BANK 1 to BANK10 as the Memory Bank to...

Страница 16: ...Recall the Memory Bank that contains the memory channel to delete 2 Press the or key to select the Memory channel to delete then press and hold the BAND key The Memory channel to be deleted from the M...

Страница 17: ...possible 1 Turn the transceiver OFF 2 Press and hold the MONI T CALL key and the PTT switch simultaneously while turn ing the transceiver ON When the LCD backlight is on release the MONI T CALL key an...

Страница 18: ...during Memory Scan Operation Some continuous carrier stations like a Weather Broadcast station will seriously impede scanner operation when using the Carrier Drop Scan Resume mode as the incoming sig...

Страница 19: ...kly in search of the Alert Tone after which regular scanning will resume for another five seconds To scan only the Weather Broadcast channels press and hold the 1 key and then press the PTT switch or...

Страница 20: ...e set 148 000 MHz into Memory Channel U01 the U designates the Upper sub band limit 4 Press and hold the BAND key 5 Press the or key to select the PMS 1 PMS number will change depending on the current...

Страница 21: ...e VFO Priority mode The display will remain on the VFO frequency but every five seconds the transceiver will check the Priority Channel memory channel for activity Every 5 seconds 4 To disable the VFO...

Страница 22: ...nd holding the 1 key 3 Press the F key then press the V M key to activate the WX Priority mode The display will remain on the WX channel frequency but every five seconds the transceiver will check the...

Страница 23: ...ncoming signal better at night Note that this will of course increase the battery consumption so be sure to switch it off during the day the default setting is ON 1 Press and hold the F key to enter t...

Страница 24: ...hannel E Two seconds after the PTT switch is released the Emergency Alarm and LED Flash will resume To disable the Emergency feature press the Emergency key momentarily or turn the transceiver off by...

Страница 25: ...g will continue every 15 or 25 seconds until the ARTS transponder is deactivated Moreover the transceiver may be programmed to transmit a callsign via CW every 10 minutes to comply with identification...

Страница 26: ...ss the or key to select the desired polling interval 15 or 25 seconds 6 Press the PTT switch to save the new setting and return to normal operation ARTS Alert Beep Options The ARTS feature permits two...

Страница 27: ...key to enable adjustment of this Set Mode Item 4 Press the F key then press the or key to select TX ON 5 Press the F key to save the new setting 6 Press the or key to select the ID 7 Press the Alphabe...

Страница 28: ...mory DTMF Tone Generation 5 Press the F key to save the new setting 6 Press the PTT switch to return to normal operation 7 While pressing the PTT switch to transmit enter the desired number on the key...

Страница 29: ...turn to normal operation To monitor and check the entered DTMF strings repeat steps 1 4 above then press the or key to select the input register and then press the MONI T CALL key Sending the DTMF cod...

Страница 30: ...ey repeatedly until the cursor returns to the first digit position We recommend that you write down the password number and keep it in a safe place in the event it is forgotten If the password is forg...

Страница 31: ...the F key to enable adjustment of this Set Mode Item 4 Press the or key to select SAVE ON or SAVE OFF default setting 5 Press the PTT switch to save the new setting and return to normal operation Disa...

Страница 32: ...he LCD If there is no key button activity within the programmed time interval the transceiver will automatically shut down When the power is on the APO timer count is reset whenever the timer setting...

Страница 33: ...Press the PTT switch to save the new setting and return to normal operation Changing the TX deviation Level In many areas of the world channel congestion has required that operating channels be closel...

Страница 34: ...rsion Scramble Asian version only The Inversion scramble feature prevents others from easily listening to the audio When activated the transceiver distorts the voice so others listening without Invers...

Страница 35: ...ansceivers the order of switch on does not matter 4 Press the or key on each transceiver to select F9 CLONE then press the F key momentarily When the Clone mode is successfully activated in this step...

Страница 36: ...feature OFF 0 5H to 12 0H Step 0 5H OFF 31 2 ARTS Selects the Beep option and the Polling Interval during ARTS operation BEEP INRANG ALWAYS OFF INTV 25SEC 15SEC BEEP OFF INTV 25SEC 24 3 BATTSAVE Selec...

Страница 37: ...to be over ridden allowing weak or non encoded signals to be heard T CALL Pressing the MONI key activates a 1750 Hz burst tone used for repeater access in many countries especially in Europe MONITOR T...

Страница 38: ...30 34 VFO SPL Enables or disables VFO Split operation VSP OFF VSP ON VSP OFF 7 35 VOX Enable Disable VOX function VOX OFF VOX ON VOX OFF 6 36 WFM RCV Broadband FM Transceiver WFM function Enables Dis...

Страница 39: ...1702 A Copyright 2017 YAESU MUSEN CO LTD All rights reserved No portion of this manual may be reproduced without the permission of YAESU MUSEN CO LTD...

Отзывы: