background image

FT-450D CAT O

PERATION

 R

EFERENCE

 B

OOK

CAT

 (C

OMPUTER

 A

IDED

 T

RANSCEIVER

) 

O

PERATION

C

ONTROL

 C

OMMAND

A computer control command is composed of an alpha-
betical command, various parameters, and the terminator
that signals the end of the control command.

Example

: Set the VFO-A frequency to 14.250000 MHz.

FA

14250000

;

Command

Parameter

Terminator

There is three for the 

FT-450D

 Command as shown below:

Set

 command: Set a particular condition

(to the 

FT-450D

)

Read

 command: Reads an answer

(from the 

FT-450D

)

Answer

 command: Transmits a condition

(from the 

FT-450D

)

For example, note the following in the case of the FA com-
mand (Set the VFO-A frequency):

To set the VFO-A frequency to 14.250000 MHz, the
following command is sent from the computer to the
transceiver:

FA14250000;

” (Set command)

To read the VFO-A frequency, the following command
is sent from the computer to the transceiver:

FA;

” (Read command)

When the Read command above has been sent, the
following command is returned to the computer:

FA14250000;

” (Answer command)

Alphabetical Commands

A command consists of 2 alphabetical characters.

You may use either lower or upper case characters. The
commands available for this transceiver are listed in the
“PC Control Command Tables” on the following pages.

Page 2

Parameters

Parameters are used to specify information necessary to
implement the desired command.

The parameters to be used for each command are prede-
termined. The number of digits assigned to each param-
eter is also predetermined. Refer to the “Control Com-
mand List” and the “Control Command Tables”  to con-
figure the appropriate parameters.

When configuring parameters, be careful not to make the
following mistakes.

For example

, when correct parameter is “

IS0+1000

” (IF

SHIFT):

IS01000

;

Not enough parameters specified (No direction (+)

given for the IF shift)

IS0+100

;

Not enough digits (Only three frequency digits

given)

IS0

_

+

_

1000

;

Unnecessary characters between parameters

IS0+10000

;

Too many digits (Five frequency digits given)

Note

: If a particular parameter is not applicable to the 

FT-

450D

, the parameter digits should be filled using any char-

acter except the ASCII control codes (00 to 1Fh) and the
terminator (

;

).

Terminator

To signal the end of a command, it is necessary to use a
semicolon (

;

). The digit where this special character must

appear differs depending on the command used.

Содержание FT-450D

Страница 1: ...FT 450D CAT OPERATION REFERENCE BOOK CAT COMPUTER AIDED TRANSCEIVER OPERATION FT 450D CAT OPERATION REFERENCE BOOK YAESU MUSEN CO LTD...

Страница 2: ...to the technical documenta tion supplied with your computer for correct data connec tion YAESU does not produce CAT System operating soft ware due to the wide variety of personal computers and operati...

Страница 3: ...ical characters You may use either lower or upper case characters The commands available for this transceiver are listed in the PC Control Command Tables on the following pages Page 2 Parameters Param...

Страница 4: ...O X X O O O O O O O O O O O O O X O O O O O X O O O X O O O X O O X O X X X X O X X O O O O X O O X O O O O O O X O O O X O O X X O O O X O O O O O O O O O X X X O X X O O O O X O O X O O O O O O X O...

Страница 5: ...ver is turned OFF Page 4 BI BI BI BI BI BREAK IN Set 1 2 3 4 5 6 7 8 9 10 B I P1 Read 1 2 3 4 5 6 7 8 9 10 B I Answer 1 2 3 4 5 6 7 8 9 10 B I P1 P1 0 Break in OFF 1 Break in ON BS BS BS BS BS BAND SE...

Страница 6: ...DIMMER OFF 1 DIMMER ON CONTROL COMMAND TABLES CH CH CH CH CH CHANNEL UP DOWN Set 1 2 3 4 5 6 7 8 9 10 C H P1 Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 P1 0 Memory Channel UP 1 Memory Chan...

Страница 7: ...S ED ED ED ED ED ENCODER DOWN Set 1 2 3 4 5 6 7 8 9 10 E D P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 P1 0 Fixed P2 01 99 Steps EU EU EU EU EU ENCODER UP Set 1 2 3 4 5 6 7 8 9 10 E...

Страница 8: ...63 064 P2 0 OFF 1 ON 0 DISABLE 1 ENABLE 00 OFF 01 hour 12 hour 000 OFF 001 sec 255 sec 0 440 Hz 1 880 Hz 2 1760 Hz 000 FIX 0 100 FIX100 or 101 LNK 50 151 LNK0 201 LNK 50 0 DISABLE 1 ENABLE 0 10 msec 1...

Страница 9: ...unction as the front panel s A B button 34 A B Set to the same function as the front panel s A B button 35 LOCK Set to the same function as the front panel s LOCK button 36 TUNE Set to the same functi...

Страница 10: ...B P1 P1 P1 P1 P1 P1 P1 P1 11 12 13 14 15 16 17 18 19 20 Read 1 2 3 4 5 6 7 8 9 10 F B Answer 1 2 3 4 5 6 7 8 9 10 F B P1 P1 P1 P1 P1 P1 P1 P1 11 12 13 14 15 16 17 18 19 20 P1 300000 60000000 Hz Page...

Страница 11: ...P1 1 3 Beacon Text Channel Number P2 Message Characters up to 40 characters CONTROL COMMAND TABLES IS IS IS IS IS IF SHIFT Set 1 2 3 4 5 6 7 8 9 10 I S P1 P2 P2 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 I S P1...

Страница 12: ...X CLAR ON P6 MODE 1 LSB 2 USB 3 CW 4 FM 5 AM 6 DATA RTTY LSB 7 CW R 8 USER L 9 DATA RTTY USB B FM N C USER U P7 0 VFO 1 Memory P8 0 CTCSS OFF 1 CTCSS ENC DEC 2 CTCSS ENC P9 Tone Number See Table 1 P10...

Страница 13: ...mmand that makes the power supply ON within two seconds after wait is done for about one second is sent NB NB NB NB NB NOISE BLANKER STATUS Set 1 2 3 4 5 6 7 8 9 10 N B P1 P2 Read 1 2 3 4 5 6 7 8 9 10...

Страница 14: ...0 OFF 1 ON R R R R RC C C C C CLAR CLEAR Set 1 2 3 4 5 6 7 8 9 10 R C Read 1 2 3 4 5 6 7 8 9 10 Answer 1 2 3 4 5 6 7 8 9 10 R R R R RG G G G G RF GAIN Set 1 2 3 4 5 6 7 8 9 10 R G P1 P2 P2 P2 Read 1 2...

Страница 15: ...SH SH WIDTH Set 1 2 3 4 5 6 7 8 9 10 S H P1 P2 P2 Read 1 2 3 4 5 6 7 8 9 10 S H P1 Answer 1 2 3 4 5 6 7 8 9 10 S H P1 P3 P3 P1 0 Fixed P2 00 10 Narrow 11 21 Normal 22 31 Wide P3 00 Narrow 16 Normal 3...

Страница 16: ...ATUS Set 1 2 3 4 5 6 7 8 9 10 Read 1 2 3 4 5 6 7 8 9 10 U L Answer 1 2 3 4 5 6 7 8 9 10 U L P1 P1 0 PLL Lock 1 PLL Unlock CONTROL COMMAND TABLES SV SV SV SV SV SWAP VFO Set 1 2 3 4 5 6 7 8 9 10 S V Re...

Страница 17: ...6 7 8 9 10 VS VS VS VS VS VFO SELECT Set 1 2 3 4 5 6 7 8 9 10 V S P1 Read 1 2 3 4 5 6 7 8 9 10 V S Answer 1 2 3 4 5 6 7 8 9 10 V S P1 P1 0 VFO A 1 VFO B Page 16 VR VR VR VR VR VOICE Set 1 2 3 4 5 6 7...

Страница 18: ...ERATION REFERENCE BOOK CAT COMPUTER AIDED TRANSCEIVER OPERATION Copyright 2017 YAESU MUSEN CO LTD All rights reserved No portion of this manual may be reproduced without the permission of YAESU MUSEN...

Отзывы: