M AINTENANCE AND ALIGNMENT
Your FL-110 Linear Amplifier has been carefully aligned and tested
at
our factory prior to shipment. The reliability of the solid state
devices used in the FL -110 should provide years of trouble-free
service if the amplifier is not abused
,
, and, normal routine maintenance
is carried out.
The
following precautions should be observed to prevent damage to
the
FL-110.
(a)
Do not exceed 14 Volts DC at the power receptacle.
When operating mobile, check the battery voltage
under load ( full output on CW) with the engine
running fast enough so that the car ammeter
shows a "charge
11•
Also, do not operate the
FL-l lO if the supply voltage is below 12 Volts DC.
( b)
Avoid direct exposure to sunshine or water.
(c)
Avoid extremely warm locations and maintain free
air circulation around the heat sink.
The FL-110 does not require realignment with normal usage. Service,
or replacement of a major component, may require subsequent realignment.
COUPLER
UNIT
TC101
VR101
TC301
VR203
BOTTOM VIEW
- 8 -
RL1
BOOSTER
UNIT
VR201
VR202