Yada AC532713 Скачать руководство пользователя страница 12

12

FCC Compliance Statement:

15A Battery Charger and Maintainer

Model: AC532713 / Responsible Party: YADA

2975 Red Hill Ave., Ste. 100, Costa Mesa, CA 92626 / Tel: 866-294-9244

This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions:

(1)This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause 

undesired operation.

WARNING: 

Changes or modifications to this unit not expressly approved by the party 

responsible for compliance could void the user’s authority to operate the equipment.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized 

modifications or change to this equipment. Such modifications or change could void the user’s 

authority to operate the equipment.

NOTE: 

This equipment has been tested and found to comply with the limits for Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and the receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is 

  connected.

- Consult the dealer or an experienced radio/TV technician for help.

OPERATING INSTRUCTIONS CONT.:

2975 Red Hill Ave., Ste. 100, Costa Mesa, CA 92626

Mon - Fri, 8AM - 5PM (Pacific Time)

Tel: 1-866-294-9244 (English only)

[email protected]

©2021 ADC Solutions Auto, LLC. All rights reserved.

www.letsyada.com

Made in China

CAN ICES-3 (B)/NMB-3(B)

ML-532713_V1

viii) 

Push Mode 

(for 12V Lead-Acid battery only) is designed for charging 

batteries with voltage 0.5V to 3.75V. At Standby mode with battery 

clamps are connected to 12V Lead-Acid battery, if the battery voltage is 

measured at 0.5V to 3.75V, both LEDs light on. Press and hold 

MODE

 

button for 3 seconds to enter Push Mode. Connect battery clamps to 

vehicle battery and the battery will be charged with maximum current of 

0.5A until the voltage is up to 3.75V and it will enter the 12V Lead-Acid 

Battery Mode for charging onwards or it will return to Standby mode and 

stop charging after 5 minutes if 3.75V can not be reached.

Содержание AC532713

Страница 1: ...User Manual 15A Battery Charger and Maintainer IMPORTANT READ THE ENTIRE INSTRUCTION MANUAL CAREFULLY AND MAKE SURE THAT YOU FULLY UNDERSTAND IT BEFORE YOU USE THE EQUIPMENT KEEP THE MANUAL FOR FUTUR...

Страница 2: ...ery maintains all battery sizes IP68 Water resistant 8 x 4 5 x 2 4 inch 203 x 114 x 60 mm charger only 3 6 lb 1657 g Input Output Charging Voltage Charging Current Reverse Current Low Voltage Detectio...

Страница 3: ...d If the mains lead is damaged it should only be replaced by a qualified electrician The charger should not be used if it is in any way damaged or malfunctioning Do not place the charger close to the...

Страница 4: ...ctric shock or fire 8 To reduce risk of electric shock unplug charger from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk WARNING RISK OF EXPLOSIVE...

Страница 5: ...all accessories in the vehicle are off so as not to cause an arc b Be sure area around battery is well ventilated while battery is being charged c Clean battery terminals Be careful to keep corrosion...

Страница 6: ...tery Clamp from battery charger to POSITIVE POS P ungrounded post of battery Connect NEGATIVE BLACK Battery Clamp to vehicle chassis or engine block away from battery Do not connect Battery Clamp to c...

Страница 7: ...ch long 6 gauge AWG insulated battery cable to NEGATIVE NEG N battery post c Connect POSITIVE RED charger Battery Clamp to POSITIVE POS P post of battery d Position yourself and free end of cable as f...

Страница 8: ...Press MODE button to start charging Error indicator will be ON for reverse polarity poor connection low voltage battery over voltage battery and temperature protection 12V Lead Acid Battery Normal Mo...

Страница 9: ...en replacing a battery 12V Repair Mode is designed for 12V LEAD ACID BATTERIES ONLY It is a battery recovery mode for repairing restoring damaged stratified and sulphated batteries 12V AGM Battery Nor...

Страница 10: ...spot on the chassis that is some distance away from the battery itself and any fuel lines 4 Connect the AC power plug of battery charger into a wall socket Battery voltage is auto detected and chargin...

Страница 11: ...l weather conditions iii 12V Lithium Battery Normal Mode is designed for 12V Lithium batteries including Lithium Iron Phosphate LiFePO4 batteries being charged under normal weather conditions PLEASE E...

Страница 12: ...ions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or mor...