Ya-man Beaute R Flash Скачать руководство пользователя страница 10

How to use each mode

How to use each mode

Warning

The device offers a safety feature which enables flash emission only when the treatment window is in 
proper contact with the skin.

The interval between each flash emission (or a row of emissions in roller mode) will differ according 
to the intensity level.

If the temperature of the treatment window rises during the treatment, the interval between each 
emission (or a row of emissions in roller mode) will increase get longer for the sake of safety.
In such a case, shut off the device and wait about ten minutes to retrieve normal interval. 

After the power remains on for ten minutes, the device will automatically shut off after an extended 
buzzer sound is emitted twice (auto-off feature).
To resume using the device, wait at least ten minutes. Failure to comply may cause a failure of the 
device.

Product functions

How to use each mode

18

17

DO NOT use the device in a dark room.

Failure to comply may cause injury to your eyes.

DO NOT emit flashes directly to your eyes.

Failure to comply may cause an eye injury.

DO NOT touch the filter (glass plate) immediately after using the flash.

As the filter becomes very hot immediately after use, touching it with your finger 
may cause it to become burned.

DO NOT use the device on the following sites.

Failure to comply may cause an accident or skin problems or physical ailments to 
occur.

Injury (scar or other dark-colored site)

 ◆

Eyeball

 ◆

Eyelid, around the eye

Acne

 ◆

Pigmentation or mole

 ◆

Eyebrow, forehead, or scalp hair  

Suntanned site

Anywhere inside the mouth, on the lip, around the pubic region, or any mucous 
membrane   

Adam’s apple

 ◆

Ear

 ◆

Nipple, areola

 ◆

Inside the belly button

 

Site where a large artery or other blood vessel can be seen

Tattoo or body-painted site

 ◆

Site to which makeup has been applied

How to use the roller mode

1

Insert the adapter plug into the 
port on the device for the 
adapter plug and insert the AC 
adapter into a wall outlet.

3

Press the power/level button and 
select the level.

 There are three flash levels.

 Start using the device from level 1 and 

gradually raise the level one by one until it gets 
to the level appropriate for yourself. Do not use 
the device at a high level right from the outset 
(see page 16).

 When the meter indicator (7 bars) is full, a 

beeping sound will be emitted to indicate that 
preparations for flash emission are complete.

2

Hold down the power/level 
button (approx. 3 seconds) to 
turn on the device.

 The meter indicator will blink in a blue color to 

signal that the device is in a standby state 
(which means that flash pulses cannot be 
generated yet).

 If the device is turned on, the internal fan will 

begin to operate with a humming sound. This 
is not a malfunction.

* Use by extending the grip of the device in a 

straight line.

Meter indicator 
(blue)

Power/level 
button

READY lamp 
(white)

Meter indicator 
(blue)

Level indicator

Power/level 
button

Grip

Adapter 
plug

each body part should be treated no more than five minutes per day.

Содержание Beaute R Flash

Страница 1: ...ts hereof make sure to store this User s Manual in an accessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person Table of contents Safety precautions 1 When using outside Japan 8 Names of parts 9 Before using 11 Treatment 16 How to use each mode 17 After treatment 23 Troubleshooting 25 After sales service 29 Product specifications ...

Страница 2: ...in question prior to using the device The following persons should not utilize the device Prohibited Safety precautions Warning 2 1 Safety precautions Safety precautions Carefully read these Safety precautions before properly utilizing the device Sensibly utilize the device in accordance with the prescribed steps If an abnormality arises immediately discontinue the use of the device and arrange to...

Страница 3: ...circuit Overloading an electric circuit prohibited Failure to comply may cause an injury Use by unattended children or persons with physical disabili ties should be avoided A minor should use the device with the consent and under the supervi sion of his or her guardian User restrictions Failure to comply may cause an injury or a failure of the device DO NOT use the device for any purpose other tha...

Страница 4: ...ice can be used should range between 10 and 40 degrees centigrade Verify the ambient temperature of the location where the device will be used The device may not correspond e f f e c t i v e l y t o t h e a m b i e n t temperature of a new location immediately after moving to the new location Failure to comply may cause the device to fail or break Ensure that the temperature of the usage environme...

Страница 5: ... Switzerland China Hong Kong India Singapore Philippines Egypt South Africa Canada U K Switzerland Thailand South Korea Singapore China Hong Kong Egypt South Africa Italy Holland Switzerland Spain Germany France India Thailand South Korea China Hong Kong Malaysia Turke U K France Australia New Zealand South Korea Taiwan China Philippines Argentina Major types of plug shapes and the countries in wh...

Страница 6: ...nd peripheral accessories are subject to change for improvement purposes without notice Names of parts Main body Vent holes Lamp head Filter yellow tinted transparent glass Glass tube Power level button Indicator panel Roller small Roller large Treatment window Vent holes Grip Flash button In single mode READY lamp In single mode Adapter plug insertion port ...

Страница 7: ...e single BODY mode The device can render unwanted hair inconspicuous and allow you to carry out a facial treatment by administering instantaneous flashes of light to the skin using a xenon lamp Use the device by selecting the mode according to the site where the device will be used Roller mode Use by extending the grip in a straight line Glide the device with the treatment window in contact with t...

Страница 8: ...ighting that is excessively dark Under a table or otherwise in the shadows Power level button On Connect the AC adapter and hold down the button approx 3 seconds to turn on the device Roller mode Standby state meter indicator will blink in a blue color Single mode The level indicator meter indicator and BODY mode FACE mode indicator will be lit For more details on modes see Modes page 11 Off After...

Страница 9: ...t to a level at which pain can be felt Use the device while adjusting the level Adjust the level since your perception will differ depending on the site where the device is used DO NOT use the device if it is set to an unreasonably high level In particular the skin of a darker skinned person or a person who has gotten suntanned will more easily absorb light For such persons failure to comply may c...

Страница 10: ...r Injury scar or other dark colored site Eyeball Eyelid around the eye Acne Pigmentation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been ...

Страница 11: ...om the device and clean the device and lamp head Clean after each use according to How to clean page 23 Refrain from taking a bath shower is permitted exercising or drinking alcoholic beverages on the day of a treatment 20 19 How to use the single mode 1 Insert the adapter plug into the port on the device for the adapter plug and insert the AC adapter into a wall outlet 4 Press the power level but...

Страница 12: ...ation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been applied When carrying out a treatment keep the following tips in mind Treatment of ...

Страница 13: ...e of the device or skin problems After Treatment Warning Unplug the AC adapter from the wall outlet before cleaning the device Failure to comply may cause an electric shock short circuit or fire Clean in a manner that prevents water from infiltrating the device Failure to comply may cause an electric shock short circuit or fire After Treatment How to store When the device will not be in use for an...

Страница 14: ...er ated Refer to Error indications page 27 An error condition is in effect Make sure that the AC adapter is properly inserted The AC adapter connection is loose The device shuts off To resume using the device wait at least ten minutes before proceeding The auto off feature is activated ten minutes after the flash button is pressed Troubleshooting Troubleshooting Condition Possible causes Solution ...

Страница 15: ...o the treatment of suntanned skin with flash pulses Remove excess hair and use the device on skin that has not been suntanned If redness or pain is manifested discontinue use immediately and cool down and moisturize the skin If there is no amelioration discontinue using the device and see a physician How many times a day can I use the device In single mode the application of flash pulses on the sa...

Страница 16: ...0 g including the lamp head Japan Main body ABS resin polycarbonate Lamp head ABS resin nylon aluminum stainless steel glass Device 1 unit AC adapter 1 unit Product specifications Disposing of the device If you wish to dispose of the device proceed in accordance with applicable local government rules governing the sorting of waste products After sales service After sales service 29 30 After sales ...