Change of Cotton Filament (76-1411030):
Please note that the cotton filament cannot be washed with the water. Water drops
would be sucked into the Pump and may cause the pump damaged within 1 to 2
months. If you wash with the water,
Cotton filament
will turn solid and will
stop the DIA60T working well. Please change
at least
once 3 to 5 days if you
use
8 hours
per day.
Change of Charcoal Filter (78-151500):
Charcoal filter will turn solid if you wash with the water. If you use 8 hours per day
that the Charcoal filter has to be changed within 3 weeks. On the other hand, if
you wash the Charcoal filter and do not dry properly, water drops will be sucked
into the Pump and may cause the pump damaged easily.
Change of Glass Solder Collector (75-160110):
Glass solder collector will be broken easily if the client knocked the DIA60T against
the desktop. The glass collector also needs to be changed every 3 to 5 months
usage.
Maintenance for Desoldering Heater and Tip:
To prevent the desoldering tip being stuck by solder, the desoldering tip has to be
cleaned by a Probe after every time usage. In such ways, desoldering tip’s life
can be lasting longer. Desolder Heater would be probably broken when you
remove the desoldering tip with a pliers careless in hot condition. Slightly
remove the tip with pliers or may use the anti-rusty cleaner when the tip clogged
with the heater and do not forced open. Please read the “
Procedure for
Cleaning Clogged Tips
” carefully on page.3 & 4 on the manual.