Xyplex 119R Скачать руководство пользователя страница 2

XYPLEX is a registered trademark of Xyplex Networks, Inc.
MAXserver and LANBUS are trademarks of Xyplex Networks, Inc.

All rights reserved.  No part of this publication may be reproduced without the prior written consent of Xyplex
Networks, Inc.  The information in this document is subject to change without notice and should not be
construed as a commitment by Xyplex Networks.  Xyplex Networksreserves the right to revise this publication,
and to make changes in content from time to time, without obligation to provide notification of such revision
or changes.  Xyplex Networks, Inc. assumes no responsibility for errors that may appear in this document.

Copyright © 1997 by Xyplex Networks, Inc.  Printed in U.S.A.

TABLE OF CONTENTS

Section

   Page

Product Prerequisites..................................................................................................................................................................1
Controls and Indicators..............................................................................................................................................................2
Installation Notes..........................................................................................................................................................................2

Safety Considerations...............................................................................................................................................2
Power Supply Planning Considerations...........................................................................................................3
Installing Power Supplies.......................................................................................................................................3
Connecting AC Power..............................................................................................................................................4
Installing and Removing the Power Input Module.....................................................................................4

Operation..........................................................................................................................................................................................4
Specifications.................................................................................................................................................................................6
Order Codes.....................................................................................................................................................................................6

ii

Содержание 119R

Страница 1: ...Product Notes Network 9000 Model 119R Redundant AC Power Input Modules Xyplex Networks Incorporated 295 Foster Street Littleton MA U S A 01640 451 0054C...

Страница 2: ...to revise this publication and to make changes in content from time to time without obligation to provide notification of such revision or changes Xyplex Networks Inc assumes no responsibility for er...

Страница 3: ...s covered in this Guide include Product Prerequisites Controls and Indicators Installation Notes Operation Restrictions Specifications Order Codes Product Prerequisites Redundant AC Power Input Module...

Страница 4: ...the bottom slot of the Network 9000 chassis the other in slot 10 Xyplex Networks recommends that you order 2 or 4 power supplies for the chassis to ensure power supply redundancy 2...

Страница 5: ...supply modules and Redundant AC Power Input Modules using the standard Network 9000 installation and removal procedures that are described in Chapter 3 of the Network 9000 Installation Guide If you a...

Страница 6: ...upplies that are associated with the functioning power input module take over the entire load To make sure that each segment of the split midplane receives power install power supplies in pairs into p...

Страница 7: ...ules in power supply slots 1 2 and 3 while the Redundant AC Power Input Module in I O module slot 10 provides AC power to the power supply modules in power supply slots 4 and 5 Both Redundant AC Power...

Страница 8: ...sor module to update its chassis parameters If you do not update the replacement module and the other power input module fails then all control storage parameters will be lost and there would a mismat...

Страница 9: ...4 F Input Voltage 110 240 Vac 50 60 Hz Power Maximum 120V 10 0A 240V 5 0A 5V 3 0A 12V 0 3A 12V 0 3A Enclosure Requirements One I O slot in a Redundant Network 9000 intra networking hub Emissions Compl...