Wear parts and accessories

SenTix

®

HW-T 900(-P)

10

ba77090s02

01/2017

7

Wear parts and accessories

Plug type

Socket, 4 pins

Shaft dimensions,

material

Shaft length 

170 mm

Shaft diameter

12 mm

Shaft material

Glass

IDS plug

Synthetic materials: Glass fiber reinforced 
Noryl, TPU, TPC-ET, POM, PVC, PEEK, 
PBT

O-ring: FPM

Contacts gold-Plated

IDS plug

Connection type

4-Pole, watertight plug connection with lock, 
reverse polarity protected

Storage

With watering cap; filled with KCl 3 mol/L, Ag

+

 free

Maintenance

equipment

Description

Model

Order no.

Reference electrolyte solution 250 mL
(KCl 3 mol/L, Ag

+

 free)

KCl-250

109 705

Pepsin cleaning solution 3 x 250 ml

PEP/pH

109 648

Connection

cableSenTix

®

HW-

T 900(-P) - meter

Description

Model

Order no.

IDS connection cable, 1.5 m

AS/IDS-1.5

903 850

IDS connection cable, 3 m

AS/IDS-3

903 851

IDS connection cable, 6 m

AS/IDS-6

903 852

IDS connection cable, 10 m

AS/IDS-10

903 853

IDS connection cable, 15 m

AS/IDS-15

903 854

IDS connection cable, 20 m

AS/IDS-20

903 855

IDS connection cable, 25 m

AS/IDS-25

903 856

IDS connection cable, 40 m

AS/IDS-40

903 857

IDS connection cable, 60 m

AS/IDS-60

903 858

IDS connection cable, 100 m

AS/IDS-100

903 859

General

accessories

Description

Model

Order no.

Blind plug for IDS plug

BPO/IDS 900

908 371

Armoring without protective hood

A 925-P

903 838

Содержание WTW SenTix ORP-T 900-P

Страница 1: ...OPERATING MANUAL ba77090s02 01 2017 SenTix HW T 900 P pH ELECTRODE WITH LIQUID REFERENCE SYSTEM AND GROUND JUNCTION OPERATING MANUAL...

Страница 2: ...SenTix HW T 900 P 2 ba77090s02 01 2017 Copyright 2017 Xylem Analytics Germany GmbH Printed in Germany...

Страница 3: ...Storing the calibration data in the sensor ensures that the correct slope and asymmetry are automatically used if the sensor is operated with different meters On the other hand different calibrated se...

Страница 4: ...Open the locking device step 1 Use your thumb and index finger to press the clips of the connector together and pull the connector out of the plug step 2 Closing the plug connection Make sure that the...

Страница 5: ...ring cap do not affect the measuring characteristics and can easily be removed with deionized water Connect the electrode to the meter Calibrate the electrode according to the operating manual of the...

Страница 6: ...to the next by taking the following measures Shortly rinse the calibration and sample beakers with the solution the beakers are to be filled with next Between measurements rinse the electrode with th...

Страница 7: ...the minimum depth of immersion Prior to the next measurement shortly rinse the electrode with the test sample or deionized water Overnight or longer Put the clean electrode in the watering cap that i...

Страница 8: ...ll amount of reference electrolyte leaks through the junction from the electrode into the test sample If the level of reference elec trolyte becomes too low with time refill it through the refilling o...

Страница 9: ...Immerse in pepsin cleaning solution PEP pH for approx 1 hour Note Make sure the level of the reference electrolyte is above that of the cleaning solu tion Hydrofluoric acid hot phosphoric acid and st...

Страница 10: ...solution 250 mL KCl 3 mol L Ag free KCl 250 109 705 Pepsin cleaning solution 3 x 250 ml PEP pH 109 648 Connection cableSenTix HW T 900 P meter Description Model Order no IDS connection cable 1 5 m AS...

Страница 11: ...returned to the disposal or return system statutory in your country electronic waste If you have any questions please contact your supplier Armoring with plastic protective hood A 925 P K 903 839 Arm...

Страница 12: ...Disposal SenTix HW T 900 P 12 ba77090s02 01 2017...

Страница 13: ......

Страница 14: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...

Отзывы: