background image

OPERATING MANUAL

ba75981e02 12/2017

MPP 910 IDS

MPP 930 IDS

MODULARE MULTIPARAMETERSONDE MIT TIEFENMESSUNG

MPP 910 IDS

MPP 930 IDS

Содержание WTW MPP 910 IDS

Страница 1: ...OPERATING MANUAL ba75981e02 12 2017 MPP 910 IDS MPP 930 IDS MODULARE MULTIPARAMETERSONDE MIT TIEFENMESSUNG MPP 910 IDS MPP 930 IDS...

Страница 2: ...2 ba75981e02 12 2017 MPP 9x0 IDS Copyright 2017 Xylem Analytics Germany GmbH Printed in Germany...

Страница 3: ...the plug connections 7 2 2 Commissioning 8 2 3 Mounting the holding shackle 9 3 Cleaning 10 4 Technical data 11 4 1 Dimensions weights 11 4 1 1 MPP 910 11 4 1 2 MPP 930 12 4 1 3 Accessories 12 4 2 App...

Страница 4: ...ic module MPP 910 IDS with one sensor plug in position 2 Basic module MPP 930 IDS with three sensor plug in positions 3 AS IDS xx connection cable between basic module and meter or sen sor and meter x...

Страница 5: ...MPP 9x0 IDS Overview 5 ba75981e02 12 2017 MPP 930 IDS MPP 910 IDS 2 1 3 4 5 6 7 8 7 8 9 9 10 11 11 10...

Страница 6: ...ad vertently disconnected With the connection cable the individual sensors can also be directly connected to the meter if necessary for calibration or firmware update Recommended fields of application...

Страница 7: ...plug connection Open the locking device step 1 Use your thumb and index finger to press the clips of the connector together and pull the connector out of the plug step 2 Closing the plug connection Ma...

Страница 8: ...the probe will go down faster Connect the basic module to the meter NOTE The connection cable without any problems withstands the tractive forces that occur when it is pulled by hand in a water body...

Страница 9: ...tective ring To do so proceed as follows sample figure of MPP 930 IDS Disconnect the connection cable from the basic module see page 7 Unscrew the protective ring pos 1 Thread the connection cable thr...

Страница 10: ...ls Then rinse the recess with a mild water jet e g wash bottle or slightly running faucet NOTE The membrane of the depth sensor is very sensitive to mechanical impacts Therefore avoid any touching of...

Страница 11: ...Dimensions in mm Weights Basic module without cable sinker and sensors all plug connections closed with blind plugs With short protective pipe approx 274 g With long protective pipe approx 355 g Sink...

Страница 12: ...ule without cable sinker and sensors all plug connections closed with blind plugs With short protective pipe approx 929 g With long protective pipe approx 1131 g Sinker Approx 1870 g Holder EH 70 SW 1...

Страница 13: ...DS multi parameter probe meets the requirements accord ing to article 3 3 of the directive 97 23 EC pressure equipment direc tive Storage conditions Storage temperature 25 50 C 13 122 F Materials Encl...

Страница 14: ...easuring ranges at 20 C 68 F 0 50 100 00 m 328 ft Resolution 0 05 m 0 16 ft Accuracy at 20 C 68 F 0 25 m 0 82 ft 1 digit Automatic density compen sation Indirectly through the integrated temperature m...

Страница 15: ...10 903 853 IDS connection cable 15 m AS IDS 15 903 854 IDS connection cable 20 m AS IDS 20 903 855 IDS connection cable 25 m AS IDS 25 903 856 IDS connection cable 40 m AS IDS 40 903 857 IDS connectio...

Страница 16: ...Wear parts and accessories MPP 9x0 IDS 16 ba75981e02 12 2017...

Страница 17: ......

Страница 18: ...uildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications ex...