SonTek – a Xylem brand
FlowTracker2 User’s Manual (January 2019)
148
Variable
Description
Units
Decimal
panels, per discharge method.
Mean Depth
Average depth calculated from the total area
and width.
m or ft
3
Area
Total area calculated from all stations or
panels, per discharge method.
m
2
or ft
2
4
Mean SNR
Average SNR of all completed stations.
Require at least 3 stations.
dB
n/a
Temp
Average temperature of all completed stations.
°C or °F
2
Vel Mean
Average station velocity, X velocity component m/s or ft/s
4
Vel Min
Minimum station velocity, X velocity
component
m/s or ft/s
4
Vel Max
Maximum station velocity, X velocity
component
m/s or ft/s
4
Height, Start
Start staff gauge reading.
m or ft
3
Height, End
End staff gauge reading.
m or ft
3
Uncertainty
Uncertainty in discharge measurement.
%
2
Largest
Uncertainty
Largest uncertainty in the discharge
uncertainty calculation.
%
2
GPS -
Latitude
GPS derived Latitude
DDD° MM' SS.SS
GPS -
Longitude
GPS derived Longitude
DDD° MM' SS.SS
Station Summary
8.3.5.4
The
Station Summary
from the data collection menu displays the completed stations in
table format. The station summary is a good reference when evaluating measurements
performed at a station against adjacent stations.
Station Summary
screen consists of tabular view of
all completed stations,
b)
To close the discharge summary report,
i).
Press the Left Soft Key.
ii).
The software will navigate to the Data
Collection Window.
Figure 8:44 - Station Summary
Properties
associated with the variables and numerical calculations performed on the
raw data collected is defined in
Table 8-13 - Station Summary
Variable
Description
Units
Decimal
Содержание SonTek FlowTracker2
Страница 107: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 106 ...
Страница 117: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 116 ...
Страница 196: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 195 ii Stationary Measurement ...
Страница 198: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 197 Measurement File Framework 12 1 1 ...
Страница 216: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 215 Variable Mode Description measurement ...
Страница 247: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 246 Configuration Changes ...
Страница 280: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 279 Figure 14 36 Edit by Station Edit a Station ...
Страница 283: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 282 ...
Страница 299: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 298 Appendix A Software Flow Diagram ...
Страница 300: ...SonTek a Xylem brand FlowTracker2 User s Manual January 2019 299 ...