The Sensus CompactRF provides a solution to integrate Sensus 

mechanical water meters with dedicated modulator blade in a smart 

metering network using wireless technology.

1. Delivery parts

Sensus CompactRF, Bayonet ring, Dial cover with cut out, 2 screws, 2 

screw seals, 1 adhesive seal

2. Installation

Mounting the Sensus CompactRF on the meter it is essential to remove 

all foils and clean the surface of the register. A screwdriver Torx (T8) or 

Slot (3.5*0.6) is recommended for mounting. The torque should be max. 

0.6 Nm. Sensus CompactRF should not get any external mechanical load.

2.1 Water meters with plastic register

Put the Sensus CompactRF on the meter, so that the two pins on top of the 

register fit exactly into the holes at the bottom of the Sensus CompactRF. 

Fit the two screws. (Fig. 

1

 and 

2

). For tamper protection fit the plastic 

seals on top of the screws (Fig. 

2

). After that change the cover (Fig. 

3

).

The bayonet ring and the adhesive seal are not used for this register type.

2.2 Water meters with glass-copper register

Mount the Sensus CompactRF with both the screws on the bayonet ring. 

For tamper protection fit the plastic seals on the top of the screws (Fig. 

4

). Remove the lid from the meter (Fig. 

5

). Fit the bayonet ring with the 

mounted Sensus CompactRF on the top of the meter register and turn it 

until it drops into place (Fig. 

6

). Push and turn the bayonet ring clockwise 

until the lever clicks into place. If required fit the adhesive seal. 

To remove the Sensus CompactRF lift the lever and rotate anticlockwise.

If the bayonet ring should be secured against removal with a fixing screw 

then the bayonet ring has to be mounted first onto the meter and fixed with 

the screw. After that mount the Sensus CompactRF on the bayonet ring as 

above. After that change the cover lid (Fig. 

7

).

3. Configuration

To make sure that the meter ID and the reading are synchronized it is 

required to configure the Sensus CompactRF after mounting to the meter.

Required tools:

•  SIRT

•  DIAVASO Config App installed at a Smartphone or Tablet

•  Encryption key (possibly when the encryption key is different from 

default)

Radio range

The typical distance between transponder and read-out device is 

500m@868MHz in line of sight. Poor installation places, obstacles in the 

radio line-of-sight and other influences like electrical interference or metal 

devices can reduce the radio range or even make radio reads impossible. 

From buildings to outside a typical range is 100 to 200 metres, while in 

an extreme case the reading range in a pit might be less than 20 metres.

4. Technical data

Technical norms &

applied standards

see Declaration of 

Conformity, RoHS, WEEE

Frequency

868 MHz

Transmitter power

25 mW

Power supply

3.6 V Lithium batteries, sealed

Battery lifetime 

Typically 12+ years

Protection class

IP 68

Operating temperature

-10 °C .... +65 °C

Storage temperature

-20 °C .... 65 °C

Dimensions

D x h - 98 mm x 85 mm

Weight

230 g

Radio protocol

SensusRF radio protocol bi-directional

FlexNet Protokoll (TFX) bi-directional

wM-Bus unidirectional

5. Disposal instructions

This product contains lithium batteries and to protect the 

environment it should not be disposed of in household 

rubbish when its serviceable life is over. Disposal 

can take place through a Sensus Service Centre. If 

however you want to take care of the disposal yourself, 

please comply with the local and national regulations 

for environmental protection.

www.sensus.com

[email protected]

        

Installation manual

Sensus CompactRF

MS 2850 INT3 / 05-2019 • 0002

EN DE ES

1

2

3

4

5

6

7

3.1

 After starting the DIAVASO 

Config  App  make  sure  that  the 

SIRT is connected via Bluetooth. 

Add (+) device and enter the 

address printed at the Sensus 

CompactRF

3.3

 After successfully retrieving the 

info from the module it is possible 

to enter the Custom meter ID that 

is lasered on the meter. In this 

example the Custom  meter ID is 

70250919

3.2

  The  DIAVASO  Config  then 

will try to communicate with the 

Sensus CompactRF.

3.4

 As a next mandatory step 

the counter reading from the 

mechanical roller counter (see 

image above) has to be transferred 

to the Sensus CompactRF. (In our 

example it is 00000.301).
Please consider the decimal 

separator.
After  these  steps  confirm  the 

settings

3.5

 When the configuration 

has been successful the new 

counter reading should appear 

and in synchronization with the 

roller counter at the meter

.

0 0 0 0 0 3 0 1